ICD-U50, ICD-U60, ICD-U70 - Sony Audio Service Manual (repair manual). Page 10

Read Sony ICD-U50 / ICD-U60 / ICD-U70 Service Manual online

10
ICD-U50/U60/U70
[How to enter the test mode]
To enter the test mode, turn ON the 
 > HOLD  switch and while
pressing the  STOP  key and the  VOL–  key at the same time, power
on (set a dry battery).
[How to exit the test mode]
Remove the battery to exit the test mode.
[Initial state of the test mode]
When the unit enters the test mode, the [Model and version number]
screen is displayed on LCD.
[Test mode flow chart]
U70  VER.1.60
System controller version (example of version 1.60)
Model information (example for ICD-U70)
1SHUF
LSP HQ
V O R H L
U70  VER.1.60
LCD
BATTERY
MEMORY INIT
INITIALIZE
INIT OK
INIT NG
BATTERY 1.500V
LCD ALL
LCD OFF
1. [Model and version number] screen (when entering the test mode)
2. [LCD] display screen 
Function select screen
Function select screen
.
>
.
>
.
>
STOP
u
All elements of LCD are turned ON.
All elements of LCD are turned OFF.
Screen display during operation
Screen display during operation
3. [BATTERY] (Battery voltage check) screen 
STOP
u
STOP
u
STOP
u
Resultant screen
Battery voltage
.
>
4. [MEMORY INIT] (Flash memory initialize) screen
u
Screen display during operation
Resultant screen
Resultant screen
Formatting and initialization have ended 
with success.
Formatting and initialization have ended
with failure.
STOP
STOP
.
>
SECTION 3
TEST  MODE
Page of 26
Display

Click on the first or last page to see other ICD-U50 / ICD-U60 / ICD-U70 service manuals if exist.