ICD-U50/U60/U70
Note on Schematic Diagrams:
• All capacitors are in 
µ
F unless otherwise noted.  (p: pF) 50 WV or
less are not indicated except for electrolytics and tantalums.
• All resistors are in 
 and 
1
/
4
 
W or less unless otherwise specified.
•        
f
: internal tolerance.
C
: panel designation.
A
: B+ Line.
• Power voltage is dc 1.5V and fed with regulated dc power supply
from battery terminal.
• Voltages and waveforms are dc with respect to ground under no-
signal (detuned) conditions.
no mark : PLAY
[           ]
  
: REC
      ∗
  
: Impossible to measure
• Voltages are taken with a VOM (Input impedance 10 M
).
Voltage variations may be noted due to normal production toler-
ances.
• Waveforms are taken with a oscilloscope.
Voltage variations may be noted due to normal production toler-
ances.
• Circled numbers refer to waveforms.
• Signal path.
F
: PB
L
: REC
Note on Printed Wiring Boards:
Y
: parts extracted from the conductor side.
: Pattern from the side which enables seeing.
(The other layers' patterns are not indicated.)
Caution:
Pattern face side:
Parts on the pattern face side seen from
(Side B)
the pattern face are indicated.
Parts face side:
Parts on the parts face side seen from
(Side A)
the parts face are indicated.