ABOUT  THE  FIRMWARE  WRITING  WHEN  REPLAC-
ING  THE  SYSTEM  BOARD
When the SYSTEM board is replaced, perform processing accord-
ing to the following procedure.
Precaution
The contents which are not opened to customers are included 
in the following procedure. After you are cautious of handling of 
information, execute work under the suffi cient administration.
1.  About the preparing of tools
Download the tools used by this work from the homepage of TISS. 
When the tools cannot be confi rmed by TISS, confi rm to the ser-
vice headquarters.
2. Setting method
Note 1: This work is impossible when battery voltage is not enough.
 
    Do work using the battery with suffi cient battery level.
Procedure:
1.  Equip IC recorder with battery.
2.  Connect PC and IC recorder with the USB cable.
IC recorder
USB connecting cable
To    (USB)
connector
PC
3.  Unzip the all fi rmware writing tools on PC.
4.  Choose the folder corresponding to the repaired IC recorder  
from the unzipped folders on PC. (Refer to following table)
Model 
name
Destina-
tion
Folder name
SX712
US model
ICD-SXx1x_V1_00_05_U_CA_LA
Canadian 
model
ICD-SXx1x_V1_00_05_U_CA_LA
AEP model
ICD-SXx1x_V1_00_05_CE7
Latin Ameri-
can model
ICD-SXx1x_V1_00_05_U_CA_LA
Chinese 
model
ICD-SXx1x_V1_00_05_CN
SX712D
US model
ICD-SXx1x_V1_00_05_U_CA_LA
Canadian 
model
ICD-SXx1x_V1_00_05_U_CA_LA
AEP model
ICD-SXx1x_V1_00_05_CE7
SX713
E model
ICD-SXx1x_V1_00_05_E
Korean 
model
ICD-SXx1x_V1_00_05_KR3
Chinese 
model
ICD-SXx1x_V1_00_05_CN
SX813
E model
ICD-SXx1xNC_V1_00_05_E
Korean 
model
ICD-SXx1xNC_V1_00_05_KR3
Chinese 
model
ICD-SXx1xNC_V1_00_05_CN
5.  Open the “fwup” folder in selected folder at step 4 on PC, and 
execute “SXnewRegionChg.js”.
6. Confi rm that “Browse For Folder” is displayed on PC, and se-
lect the root folder of IC recorder connected by USB.
 (In 
following 
fi gure, IC recorder is recognized as “IC RE-
CORDER (F:)”)
7.  Click “OK” button on PC.
8. Confi rm that the screen of IC recorder disappears for a moment 
and IC recorder reboots.
 Note 
2: IC recorder is not turned off by any means until IC recorder 
reboots.
9. Confi rm that “Region write fi nished!” is displayed on PC, and 
click “OK” button.
10. Open the “fwup” folder in selected folder at step 4 on PC, and 
execute “SXnew_Updater.js”.