15. Sleep test
• A transition to the sleep state is made for measurement of the
• A transition to the sleep state is made for measurement of the
standby current.
LCD DISPLAY
B
ENTER
<SLEEP>
Please Enter
Please Enter
B
ENTER
SET UP
<SLEEP>
SLEEP : NORMAL
• A transition to SLEEP state selection is made after power-on.
[PLAY]: The mode is determined. A transition to SLEEP is
made.
• The transition from this mode to other mode is inhibited.
• To exit this mode, disconnect power (unplug the battery.)
• When the WakeUP signal is detected, the system is rebooted.
• To exit this mode, disconnect power (unplug the battery.)
• When the WakeUP signal is detected, the system is rebooted.
16. BATT Lift test
• A result of measurement made through the battery life mea-
• A result of measurement made through the battery life mea-
surement F/W is indicated on the LCD.
• It is impossible to check this in service because the measure-
ment FW is required.
17. CHG LOG test (Not used in this set)
• A log for charging held in the SRAM is copied to the eMMC.
• A log for charging held in the SRAM is copied to the eMMC.
LCD DISPLAY
B
ENTER
<CHG LOG>
Please Enter
Please Enter
<CHG LOG>
Success
• After power-on, a log for charging is copied to the eMMC.
• An OK/NG result is displayed.
• Press the [
• An OK/NG result is displayed.
• Press the [
x
] button to return to the test mode screen.
18. MENU INIT lnit
• The menu setting is reset to the factory setting.
• The menu setting is reset to the factory setting.
LCD DISPLAY
B
ENTER
<MENU INIT>
Please Enter
Please Enter
<MENU INIT>
Formatting...
Formatting...
<MENU INIT>
Succes
• A transition to the initialization wait state is made after MENU
INIT.
[PLAY]: The mode is determined.
The initialization is executed.
• An OK/NG result is displayed.
• Press the [
• Press the [
x
] button to return to the test mode screen.