Read Sony ICD-P330F Service Manual online
6
ICD-P330F
SECTION 3
TEST MODE
1. Outline of the TEST MODE
The TEST MODE is designed to help verify the set when servicing
it.
The TEST MODE is only menu driven to select modes for servicing.
The TEST MODE is designed to help verify the set when servicing
it.
The TEST MODE is only menu driven to select modes for servicing.
2. Entering and Canceling the TEST MODE
With the power on, turn on the [HOLD] switch while pressing the
With the power on, turn on the [HOLD] switch while pressing the
x STOP
button and the
•
DISPLAY/MENU
button at the same time.
3. Canceling the TEST MODE
The TEST MODE can be cancelled by turning off the power
(unplugging the dry battery).
The TEST MODE can be cancelled by turning off the power
(unplugging the dry battery).
4. Menu Key Designation
The menu has the five modes described below. The following keys
are assigned on the initial screen (version display).
The menu has the five modes described below. The following keys
are assigned on the initial screen (version display).
5. Key Assignment
From within TEST MODE, the intended menu can be entered by
using the appropriate one key of the following key.
From within TEST MODE, the intended menu can be entered by
using the appropriate one key of the following key.
LCD Test (All On
yAll Off)
•
DISPLAY/MENU
BEEP Test (1.3 kHz)
FM•i/5
HQ-DSP LOOP
zX REC/PAUSE
SP-DSP LOOP
– .
LP-DSP LOOP
> +
USB Test
Nx PLAY/STOP(ENTER)
REST MENU Test
DIVIDE
Initial Display from each mode
x STOP
5-1. Initial Display in TEST MODE
LCD indications (destination information, memory capacity, CPU
FW information and MIC sens) when TEST MODE is entered:
LCD indications (destination information, memory capacity, CPU
FW information and MIC sens) when TEST MODE is entered:
5-2. LCD Test
To enter the LCD Test, press the
To enter the LCD Test, press the
•
DISPLAY/MENU
button. The LCD
Test has two modes: All On and All Off First all the indicators are
on. All the indicators are off when the button is pressed again.
on. All the indicators are off when the button is pressed again.
Press the
x STOP
button to return to the initial display (destination
information, memory capacity, CPU FW information and MIC sens).
5-3. BEEP Test
To enter the BEEP Test, press the
To enter the BEEP Test, press the
FM • i/5
button.
Press the
x STOP
button to return to the initial screen (memory and
CPU version).
5-4. DSP LOOP
The DSP LOOP modes can be entered selectively by pressing the
appropriate one of the following three keys.
Within the LOOP test menu, “LOOP” is displayed. The sensitivity
character H or L is displayed depending on the position into which
the [HOLD] switch is placed.
The sensitivity H is displayed when [HOLD] switch is in the ON
position. The sensitivity L is displayed when [HOLD] switch is in
the OFF position.
The DSP LOOP modes can be entered selectively by pressing the
appropriate one of the following three keys.
Within the LOOP test menu, “LOOP” is displayed. The sensitivity
character H or L is displayed depending on the position into which
the [HOLD] switch is placed.
The sensitivity H is displayed when [HOLD] switch is in the ON
position. The sensitivity L is displayed when [HOLD] switch is in
the OFF position.
To change the DSP LOOP test mode, press the
x STOP
button, then
select the
zX REC/PAUSE
button,
–
.
button, or
>
+
button.
In a DSP Test mode, to select another DSP Test mode and to select
the other sensitivity, the
the other sensitivity, the
x STOP
button also has to be pressed.
Memory capacity
(128-128 MB)
(64-64 MB)
(32-32 MB)
(16-16 MB)
(128-128 MB)
(64-64 MB)
(32-32 MB)
(16-16 MB)
MIC sens
Destination
information
information
CPU FW information
H
ALL ON
•
DISPLAY/MENU
Switch between
the modes.
the modes.
A B C D
REQ
FM
LP
EASY-S
REC
REMAIN
REMAIN
LOCAL YH
MM MHz DS
DATE
SPHQ
L
H
ALL OFF
Beep: Frequency 1.3 kHz only
zX
REC/PAUSE
.
>
HQ
H
LP
H
SP
H