ICD-LX30 - Sony Audio Service Manual (repair manual). Page 12

Read Sony ICD-LX30 Service Manual online

ICD-LX30
12
4-15. SLEEP
It can change into the sleep state for standby current value mea-
surement.
Note: It cannot move to other modes from this mode.
Procedure:
1.  Enter the test mode.
2.  Press the [FF/
M
] or [FR/
m
] keys to select the “SLEEP”, 
and press the [PLAY/ENTER/
N
] key.
3.  The sleep state selection screen is displayed.
 
This unit shifts to the sleep state by pressing the [PLAY/
ENTER/
N
] key again.
<SLEEP>
SLEEP:NORMAL
Excuting...
LCD Display
*Displayed characters/values are example.
Releasing method:
Remove battery.
4-16. BATT 
LIFE
Not used for the servicing.
4-17. WRITER 
VER
Not used for the servicing.
4-18. CHG 
LOG
Not used for the servicing.
4-19. MENU 
INIT
This unit can return to the factory shipment settings.
Procedure:
1.  Enter the test mode.
2.  Press the [FF/
M
] or [FR/
m
] keys to select the “MENU 
INIT”, and press the [PLAY/ENTER/
N
] key.
3.  Initialization of this unit is performed.
 
“Success” is displayed, and this unit reboots.
Page of 18
Display

Click on the first or last page to see other ICD-LX30 service manuals if exist.