ICD-FX88 - Sony Audio Service Manual (repair manual). Page 13

Read Sony ICD-FX88 Service Manual online

ICD-FX88
13
4-12. KEY
Operation of keys and switches can be checked, and this unit can 
return to the factory shipment settings.
Note 1: It cannot move to other modes from this mode.
Procedure:
1.  Enter the test mode.
 
(Refer to “SETTING THE TEST MODE” on page 9)
2. Press 
the 
[
>
] or [
.
] keys to select the “KEY”, and press 
the [ENTER/
N
] key.
3.  Whenever any keys of this unit are pressed or any switches of 
this unit are slid, the button count decreases.
 
(Displayed characters/values in the following fi gure are ex-
ample)
LCD Display
Button count
Confirmed key name
 
Target keys:
 
[
x
], [>], [.], [ENTER/
N
], [REC/PAUSE/
z
], 
 
[
 
A-B], [VOL +], [VOL –], [ DISPLAY/ MENU]
 
Target switches:
 
[SCENE] (“MY VOICE” direction, “CLASS” direction), 
 
[HOLD•POWER ON/OFF] (“POWER ON/OFF” direction, 
return from “POWER ON/OFF” direction, “HOLD” direction, 
return from “HOLD” direction)
4.  After all the keys and switches are decided, initialization is 
performed.
5.  After “ACCESS” is displayed, “OK” is displayed and this unit 
reboots.
LCD Display
Note 2: This unit is not initialized when operation indicator blinks in red 
color.
Releasing method:
Remove battery.
4-13. INIT
This unit can return to the factory shipment settings.
Procedure:
1.  Enter the test mode.
 
(Refer to “SETTING THE TEST MODE” on page 9)
2. Press 
the 
[
>
] or [
.
] keys to select the “INIT”, and press 
the [ENTER/
N
] key.
3.  Initialization is performed.
 
After “ACCESS” is displayed, “OK” is displayed and this unit 
reboots.
LCD Display
Page of 18