ICD-BX112 - Sony Audio Service Manual (repair manual). Page 7

Read Sony ICD-BX112 Service Manual online

ICD-BX112
7
SECTION  2
TEST  MODE
1.  Outline of the TEST MODE
The TEST MODE is designed to help verify the set when servic-
ing it.
The TEST MODE is only menu driven to select modes for servic-
ing.
2.  Entering and Canceling the TEST MODE
With the power on, turn on the [HOLD] switch while pressing the 
[
x
] button and the [
/
MENU] button at the same time.
3.  Canceling the TEST MODE
The TEST MODE can be cancelled by turning off the power (un-
plugging the dry battery.)
4.  Flow Chart of TEST MODE
Select the desired item by using the [
>
 +]/[– 
.
] button, and 
press the [
N
 ENTER] button to set the selection.
VERSION
]
]
m
02
DPC
VERSION
KEY COUNT
DPC
COUNT
m
DPC
KEY
m
KEY
m
DPC
MAIN MENU
U 0.06.0
DPC
BATTERY LIFE
BATLIFE
m
DPC
RTC
RTC
m
DPC
SLEEP
SLEEP
m
LCD,LAMP
m
DPC
BEEP
DPC
m
BEEP
LCD
m
DPC
AUDIO LOOP
AUDIO
m
DPC
BATT AD,DCIN
BATT DC
START
TEST MODE
END
TEST MODE
Turn off the power
(Remove the batteries)
5.  Operation Display of respective menus
The operational and screen information about the respective menus 
is described.
5-1.  Initial Display in TEST MODE
LCD indications (destination information, memory capacity, CPU 
FW version information, MIC sens and ALC) when TEST MODE 
is entered:
m H
DPC
02
U 1.00.00
Model information
(01 : 1GB)
Memory capacity
This display used to “5-4. Audio Loop”.
(02 : 2GB)
(04 : 4GB)
(00 : Access Error)
CPU FW version information
DPC
VOL.10
(DPC : ON)
(         : OFF)
ALC
Volume
(VOL.00~30)
MIC sens
m H
Page of 36
Display

Click on the first or last page to see other ICD-BX112 service manuals if exist.