ICD-B500 - Sony Audio Service Manual (repair manual). Page 7

Read Sony ICD-B500 Service Manual online

7
ICD-B500
To change the sensitivity again, press the  
x STOP
  button and change
the [HOLD] switch.
In a DSP Test mode, changing the mode and changing the sensitivity
require the  
x STOP
  button be pressed.
5-5. RESET MENU
To enter the RESET MENU test, press the [DIVIDE] button.
When all of the buttons or controls located on the set are operated,
the system shows “Ok” if all of them are normally operated.
An operation of a switch is indicated by the number for verification
in order to make a simple indication.
Note 1: When 10 different operations of the switches are normally
made in any order (regardless of the order that pushbuttons
are pressed and the slide switch is set to ON and OFF),
the system shows “Ok”.
Note 2: Clear memory when “ACCESS” is blinking on the display.
(Do this before “Ok” is shown.) To exit from this menu,
the power has to be turned off (battery to be removed).
Sensitivity H
HOLD
ON
OFF
H
Sensitivity L
HOLD
L
r
r
Press  DIVIDE  button.
Indication after  DIVIDE  
button is pressed.
Indication after  DISPLAY/MENU
button is pressed.
Indication after  zX REC/PAUSE  
button is pressed.
Indication after  HOLD   is 
set to OFF.
Indication after  HOLD  is 
set to ON.
 t If any key is not pressed,
       the system waits for the key
       to be pressed.
Clear memory when “ACCESS” is
blinking on the display.
The system shows “Ok”. 
••••••
r
r
r
H
Page of 20
Display