– 18 –
Pin No.
Pin Name
I/O
Function
74
XBCK
O
DSP bit clock signal output to the MSM7590L (IC101)
75
RTCDI
I
Serial data input from the RS5C348A (IC703)
76
RTCDO
O
Serial data and DSP register control data output to the RS5C348A (IC703)
77
RTCCLK
O
Serial data and DSP register control data transfer clock signal output to the RS5C348A (IC703)
78
IC
Fixed at “L”
79
X2
O
Main system clock output terminal (5 MHz)
80
X1
I
Main system clock input terminal (5 MHz)
81
VDD1
Power supply terminal (+3.3V)
82
XT1
I
Sub system clock input terminal (32.768 kHz)
83
XT2
O
Sub system clock output terminal (32.768 kHz)    Not used (open)
84
XRESET
I
System reset signal input from the reset signal generator (IC505)    “L”: reset
For several hundreds msec. after the power supply rises, “L” is input, then it changes to “H”
85
SYNCIN
I
Interrupt input terminal of the DSP X (R) sync
86
WAKEUP
I
Key interruption processing start signal input terminal
87
RTCINT
I
Interrupt input from the RS5C348A (IC703) (2 Hz)
88
O
Not used (open)
89
LPMODE
O
Filter selection signal output terminal    “L”: SP mode, “H”: LP mode
90
AVREFO
O
Reference voltage output terminal (for A/D converter)
91 to 98
FMIO0 to FMIO7
I/O
Two-way data bus with the flash memory (IC702) (bit 0 to bit 7)
99
AVSS
Ground terminal (for A/D converter)
100
BATT
I
Dry battery voltage detection signal input terminal (A/D input)