HT-SF1200, HT-SS1200, STR-KS1200 - Sony Audio Service Manual (repair manual). Page 9

Read Sony HT-SF1200 / HT-SS1200 / STR-KS1200 Service Manual online

STR-KS1200
STR-KS1200
9
9
SECTION  4
ELECTRICAL  CHECK
FM  AUTO  STOP  CHECK
signal
generator
set
Procedure:
1.  Turn on the set.
2.  Input the following signal from signal generator to FM antenna 
input directly.
Carrier frequency: A = 87.5 MHz, B = 98 MHz, C = 108 MHz
Deviation  : 75 kHz
Modulation : 1 kHz
ANT input  : 1 kHz
Note:  Use 75 ohm coaxial cable to connect signal generator and the set. 
You cannot use video cable for checking.
 
Use signal generator whose output impedance is 75 ohm.
3.  Set to FM tuner function and scan the input FM signal with 
automatic scanning.
4. Confi rm that input frequency of A, B and C are detected and 
automatic scanning stops.
When the station signal is received in good condition, automatic 
scanning stops.