HT-DDW3000, STR-KM3000 - Sony Audio Service Manual (repair manual). Page 11

Read Sony HT-DDW3000 / STR-KM3000 Service Manual online

STR-KM3000
STR-KM3000
11
11
SECTION  5
ELECTRICAL  CHECK
FM  AUTO  STOP  CHECK
signal
generator
set
Procedure:
1.  Turn on the set.
2.  Input the following signal from signal generator to FM antenna 
input directly.
Carrier frequency : A = 87.5 MHz, B = 98 MHz, C = 108 MHz
Deviation 
: 75 kHz
Modulation 
: 1 kHz
ANT input 
: 1 kHz
Note:  Use 75 ohm coaxial cable to connect signal generator and the set. 
You cannot use video cable for checking.
 
Use signal generator whose output impedance is 75 ohm.
3.  Set to FM tuner function and scan the input FM signal with 
automatic scanning.
4. Confi rm that input frequency of A, B and C are detected and 
automatic scanning stops.
When the station signal is received in good condition, automatic 
scanning stops.
SECTION  4
TEST  MODE
FL  CHECK  MODE
All fl uorescent segments are tested. When this test is activated, all 
segments turn on at the same time, then each segment turns on one 
after another.
Procedure:
1.  When pressing the [INPUT MODE] and [SLEEP] buttons, 
press the [
?/1
] button to turn on the main power. 
2.  All segments turn on.
3.  Turn the [INPUT SELECTOR] dial. 
4.  Test pattern 1 turn on.
5.  Turn the [INPUT SELECTOR] dial once again. 
6.  Test pattern 2 turn on.
7.  Turn the [INPUT SELECTOR] dial once again. All segments 
turn off. 
8.  Every turning of the [INPUT SELECTOR] dial turns on each 
segment one after another on the same order.
S.F.  CLEAR  MODE
The preset sound fi led is cleared when this mode is activated. Use 
this mode before returning the product to clients upon completion 
of repair.
Procedure:
1.  While pressing the [2CH] button, press the [
?/1
] button to turn 
on the main power. 
2.  The message “S.F. CLR.” appears and initialization is per-
formed. 
VERSION  CHECK  MODE
When this mode is used the model, the destination and the software 
version number are displayed.
Procedure:
1.  While pressing the [INPUT MODE] and [DIMMER] buttons, press 
the [
?/1
] button to turn on the main power. 
2.  The model, the distination and the software version number 
appear. 
KEY  CHECK  MODE
This mode is used to check the key.
Procedure:
1.  While pressing the [INPUT MODE] and [MUSIC] buttons, 
press the [
?/1
] button to turn on the main power. 
2.  The message “REST 08” appears.
3.  Every pressing of any button other than the [
?/1
] button counts 
down the buttons. The buttons which are already counted once 
are not counted again.
4.  When all buttons are pressed, the message “REST 00” ap-
pears.
SWAP  ALL MODE
The signal will be swapped to all channels so that all speakers will 
have sound output.
Procedure:
1.  While pressing the [DIMMER] and the [DISPLAY] buttons 
simultaneously, press the power [
?/1
] button to turn on the 
main power.
2.  The message “SWP.ALL” appears.
SHIPMENT  MODE
All preset contents are cleared when this mode is activated.  Use 
this mode before returning the product to clients upon completion 
of repair.
Procedure:
1.  While pressing the [SLEEP] and [DISPLAY] buttons, press the 
[
?/1
] button to turn on the main power. 
2.  The message “CLEARING” appears.
DCAC  FACTORY  TEST  MODE
DCAC Factory Test mode have two stages:
1.  DCAC DSP Data Line Checking 
2.  DCAC board Checking
Factory Test System Setup
1.  When power off : 
 
While pressing the [MUSIC] and [DISPLAY] buttons, press 
the [
?/1
] button to turn on the main power .
 
“DCAC  FTM” appears.  
 
Afterward, press the [DIMMER] to start DCAC factory test 
mode.
SPK Front Left
DCAC MIC
Receiver
DSP Data Line
Check
Start
Pass
Pass
Auto Cal Mic
Check
END
MEMORY
L
C
R
SL
S SR
SB SBR
SBL
SW
LFE
SP A
SP B
CAT
NEO:6 SAT
D.RANGE
RDS ST
MONO
DTS-ES
96 / 24
HDMI COAX
D EX
OPT
PL II x
PL
dB
k Hz
mft.
MHz
L
R
S
LFE
SP B
NEO:6
D.RANGE
RDS ST
MONO
COAX
PL II x
k
m
MHz
MEMORY
C
SL
SR
SB SBR
SBL
SW
CAT
DTS
D
PL
dB
Hz
ft.
ST
1.  DCAC DSP Data Line Checking
After press the [DIMMER] button, DCAC Factory test mode will 
start, below display will show:
 
“DCAC   x” 
x = 1, 2, 3, 4
   If there is error happen, below display will show:
 
“ERR SD0x”  x = 1 
→ D1501 or R1530 problem
 
 
x = 2 
→ D1502 problem 
 
 
x = 3 
→ D1503 problem 
2.  DCAC board Checking
Connect front left speaker of the receiver and AUTO CAL micro-
phone. Turn [MASTER VOLUME] jog, there will be test tone 
sound output from front left speaker, and the display will change 
accordingly.
 
“AD - xxx” 
xxx = 0 to 255 (depends on loudness of test tone)
RE-BOX  CLASSIFICATION  TEST  MODE
Procedure:
1.  While pressing the [MOVIE] and [DISPLAY] buttons, press 
the [
?/1
] button to turn on the main power.
2.  The message “R.BOX
[][][]XX” appears. 
 
XX: times set powered on
VACS  CONTROL  TEST  MODE
The VACS feature of the amplifi er is turned off purposely.
Procedure:
1.  While pressing the [INPUT MODE] and [MOVIE] buttons, 
press the [
?/1
] button to turn on the main power.
2.  The message “VACS OFF” appears.
Page of 54
Display