Read Sony HMD-A240 Service Manual online
Part Replaced ( )
HV ADJ
RV501
Part Replaced ( )
D Board
T501, IC501, RV501, R540,
R541, R542, R544, R564, R567,
R568, C532, C534, C539, C553,
C554, C555, C556, C558, C561
R541, R542, R544, R564, R567,
R568, C532, C534, C539, C553,
C554, C555, C556, C558, C561
HV Regulator
Circuit
Circuit
D Board
T501, R510, R543, R547, R549,
R552, R595, D515, D517, C540,
C542, C544, IC607, IC901, C951
R552, R595, D515, D517, C540,
C542, C544, IC607, IC901, C951
HV HOLD
DOWN Circuit
DOWN Circuit
D Board
T501, R545, R546, R548, R550,
R596, R934, C535, C541, IC605,
IC607, IC901
R596, R934, C535, C541, IC605,
IC607, IC901
Beam Current
Protector Circuit
Protector Circuit
— 10 —
HMD-A240
2-2. HV PROTECTOR CIRCUIT CHECK
1. ConÞ rm that the voltage between cathode of D517 and GND is
more than 27.0 VDC.
2. Using an external DC Power supply, apply the volt age shown below
between cathode of D517 on D Board and GND, and conÞ rm that
the HV Hold-Down circuit works (Raster disappears). Apply DC
Voltage: Less than 35.9 VDC.
the HV Hold-Down circuit works (Raster disappears). Apply DC
Voltage: Less than 35.9 VDC.
Check Condition
• Input voltage: 120 ± 2 VAC
• Input signal: (fH =69 kHz), White Cross Hatch
• Controls: CONT (max) & BRT (center)
• B+ Voltage: 179 ± 3.0 VDC
• Input voltage: 120 ± 2 VAC
• Input signal: (fH =69 kHz), White Cross Hatch
• Controls: CONT (max) & BRT (center)
• B+ Voltage: 179 ± 3.0 VDC
2-3. BEAM PROTECTOR CHECK
(SOFTWARE LOGIC)
1. Using an external current source, apply < 1.55mA between pin
11
of FBT (T501) and GND, and conÞ rm that the raster fades out.
Check Condition
• Input voltage: 120 ± 2 VAC
• Input signal : (fH = 69 kHz), White Cross Hatch
• Controls: CONT (max) & BRT (center)
• Input voltage: 120 ± 2 VAC
• Input signal : (fH = 69 kHz), White Cross Hatch
• Controls: CONT (max) & BRT (center)
2-4. B+ VOLTAGE CHECK
1. Input white cross hatch (fH = 69 kHz) signal.
2. CONT (max) & BRT (center).
3. Input voltage: 110 ± 10 VAC.
2. CONT (max) & BRT (center).
3. Input voltage: 110 ± 10 VAC.
Note: Use NF power supply or make sure that dis tortion factor is
3% or less.
3% or less.
4. ConÞ rm that the voltage is within the range shown below:
Standard voltage: 179 ± 3.0 VDC
SECTION 2: SAFETY RELATED ADJUSTMENTS
When replacing parts shown in the table below, the following
operational checks must be performed as a safety precaution
against X-ray emissions from the unit.
operational checks must be performed as a safety precaution
against X-ray emissions from the unit.
Allow the unit to warm up for one minute prior to checking the
following conditions.
following conditions.
2-1. HV REGULATOR CHECK
1. Input white cross hatch signal (fH = 80 kHz).
2. CONT maximum and BRT center.
3. Cut off Screen VR (G2).
4. Input voltage: 120 ± 2 VAC.
5. ConÞ rm that the voltage is within the voltage range shown below:
2. CONT maximum and BRT center.
3. Cut off Screen VR (G2).
4. Input voltage: 120 ± 2 VAC.
5. ConÞ rm that the voltage is within the voltage range shown below:
Standard voltage: 26.0 +0.3, -0.5 kV
6. When replacing components identiÞ ed by Y , make sure to recheck
the High Voltage.
7. Verify the High Voltage as shown above (26.0 +0.3, -0.5 kV) is
within speciÞ cation. If not, set H. SIZE data at minimum (-127)
and then adjust RV501 on D Board (Adjustment target = 26.0 ±
0.2 kV).
and then adjust RV501 on D Board (Adjustment target = 26.0 ±
0.2 kV).
8. After adjusting the High Voltage within speciÞ cation, put the RV
cover on RV501 as shown below and apply sufÞ cient amount of RTV
around RV501.
around RV501.
RV501
104