Read Sony HCD-ZX10D / LBT-ZX10D Service Manual online
24
HCD-ZX10D
3. Mecha Aging
On the Test Mode Menu screen, selecting [3] executes the aging of
the mechanism deck.
the mechanism deck.
### Aging Test MENU ###
** Pls use over 40min.CD **
Operation Menu
1. Open/Close Test
Exit: RETURN
1. On the Aging Test MENU screen, press the [1] key on the
remote commander to display the Open/Close Test screen.
2. Insert discs and press the [ENTER] key on the remote
commander.
3. Is starts the aging.
During aging, the disc number, operating status and repeat
cycle are displayed. Aging can be aborted at any time by
pressing the [RETURN] key. After the operation is stopped,
press the [RETURN] key to return to the Aging Test MENU.
pressing the [RETURN] key. After the operation is stopped,
press the [RETURN] key to return to the Aging Test MENU.
2-7. Disc Check Memory
Disc Check Memory
1. SL Disc check
2. CD Disc check
3. DL Disc check
Exit: RETURN
On this screen, measure the mirror time of chucked disc, and write
to the EEPROM.
to the EEPROM.
2-8. Error Rate Display
Error Rate Display
UC CR Address
PI1 Err Now xx xxxx xxxxxxxx
Max xx xxxx xxxxxxxx
Avg xx xxxx xxxxxxxx
PI2 Err Now xx xxxx xxxxxxxx
Max xx xxxx xxxxxxxx
Avg xx xxxx xxxxxxxx
PO Err Now xx xxxx xxxxxxxx
Max xx xxxx xxxxxxxx
Avg xx xxxx xxxxxxxx
Exit: RETURN
On this screen, measure and display the error rate.
UC : Incorrect value
CR : Correct value
CR : Correct value
2-9. SACD Water Mark Check
SACD Water Mark Check
PSP AMP
PSN
Adjust Error Failed
Start: ENTER Stop: RETURN
On this screen, measure the PSP AMP value and PSN value of SACD
water mark.
water mark.