– 22 –
SECTION  7
DIAGRAMS
7-1.
IC  PIN  FUNCTION  DESCRIPTION
 MAIN BOARD  IC301  
µ
PD780018YGF-028-3BA (SYSTEM CONTROLLER)
Pin No.
Pin Name
I/O
Function
1
TA-MUTE
O
Line muting on/off control signal output terminal    “L”: muting on
2
DBFB-H/L
O
DBFB normal/high selection signal output to the M62427FP (IC201)                                               
“L”: DBFB high, “H”: DBFB low
3
427-LAT
O
Serial data latch pulse output to the M62427FP (IC201)
4
K-CON-LAT
O
Serial data latch pulse output terminal    Not used (open)
5
K-CON-ON
O
On/off selection signal output of the key control circuit    “L”: on    Not used (open)
6
F-RELAY
O
Relay drive signal output for the speaker protect    “H”: on
7
R-RELAY
O
Relay drive signal output for the speaker protect    “H”: on    Not used (open)
8
PL-RELAY
O
Relay drive signal output for the speaker protect    “H”: on    Not used (open)
9
TEST
I
Test terminal    Connected to ground
10
X2
O
Main system clock output terminal (5 MHz)
11
X1
I
Main system clock input terminal (5 MHz)
12
VDD
Power supply terminal (+5V)
13
XT2
O
Sub system clock output terminal (32.768 kHz)
14
XT1
I
Sub system clock input terminal (32.768 kHz)
15
RESET
I
System reset signal input from the reset signal generator (IC302)    “L”: reset                                   
For several hundreds msec. after the power supply rises, “L” is input, then it changes to “H”
16
(INT/IN)
I
Connected to ground
17
(INT/IN/OUT)
I
Connected to ground
18
SCOR
I
Subcode sync (S0+S1) detection signal input from the CXD2519Q (IC103)
19
SOFT-TEST
O
Output terminal for the software test (open)
20
AC-CUT
I
AC off detection signal input from the reset signal generator (IC302)
21
RDS-INT
I
Serial data reading clock signal input for the radio data system    Not used (fixed at “L”)
22
RDS-DATA
I
Serial data input for the radio data system    Not used (open)
23
VDD
Power supply terminal (+5V)
24
AVDD
Power supply terminal (+5V) (for A/D conversion)
25
ADJ
I
Setting terminal for the CD test mode    Normally: fixed at “H”
26
A-SHUT
I
Shut off detection signal input from the deck-A side reel pulse detector (Q1001)
27
B-SHUT
I
  Shut off detection signal input from the deck-B side reel pulse detector (Q1002)
28
B-HALF
I
Detection input from the deck-B half detect switch (S1006)
29
CLK-CHECK
I
Not used (fixed at “L”)
30
SPEC-IN
I
Setting terminal for the version
31
ADJ2
I
Setting terminal for the CD test mode    Normally: “L”
32
DEMO-MODE
I
Setting terminal for the demonstration H/L   Fixed at “L”
33
AVSS
Ground terminal (for A/D conversion)
34
SQ-DATA-IN
I
Sub-code Q data input from the CXD2519Q (IC103)
35
NCO
O
Not used (open)
36
SQ-CLK
O
Sub-code Q data reading clock signal output to the CXD2519Q (IC103)
37
SW-ON/OFF
O
Super woofer speaker on/off control signal output terminal    Not used (open)
38
FUNC1
I
Setting terminal for the function 1    Fixed at “L”
39
FUNC2
I
Setting terminal for the function 2    Fixed at “L”
40
VSS
Ground terminal
41
VOL-LAT
O
Serial data latch pulse output terminal    Not used (open)
42
PL-LAT
O
Serial data latch pulse output terminal    Not used (open)
43
COM-DIN
I
Serial data input terminal    Not used (fixed at “L”)
Page of 78