HCD-VP700 - Sony Audio Service Manual (repair manual). Page 17

Read Sony HCD-VP700 Service Manual online

18
HCD-VP700
2. Turn the adjustment screw and check output peaks. If the peaks
do not match for L-CH and R-CH, turn the adjustment screw
so that outputs match within 1dB of peak.
3. Mode:  Playback
4. After the adjustments, apply suitable locking compound to the
pats adjusted.
Adjustment Location: Playback Head (Deck A).
Record/Playback/Erase Head (Deck B).
Tape Speed Adjustment
DECK B
Note: Start the Tape Speed adjustment as below after setting to the test
mode.
In the test mode, the tape speed is high during pressing the
 CD SYNC HI-DUB 
 button.
Procedure:
1. Turn the power switch on.
2. Press the x button,  DISPLAY  button and  DISC 3  button
simultaneously.
(Cursor segment flash on the FL display tube.)
To exit from the test mode, press the ?/1 button.
Mode:  Playback
1. Insert the WS-48B into the deck B.
2. Press the Y button on the deck B.
3. Press the  CD SYNC HI-DUB  button in playback mode.
Then at HIGH speed mode.
4. Adjust RV1001 on the LEAF SW board do that frequency
counter reads 6,000 
± 30 Hz.
5. Press the  CD SYNC HI-DUB  button.
Then back to NORMAL speed mode.
6. Adjust RV1002 on the LEAF SW board so that frequency
counter reads 3,000 
± 15 Hz.
Adjustment Location:  LEAF SW board
Playback level Adjustment
DECK A      DECK B
Procedure:
Mode:  Playback
Deck A is RV302 (L-CH), Deck B is RV303 (L-CH) so that
adjustment within adjustment level as follows.
Adjustment Level:
CN301 PB level:  334 to 375 mV (–6.8 dB 
± 0.5 dB) level
difference between the channels:  within 
±0.5 dB
Adjustment Location:  MAIN board
Sample Volue of Wow and Flutter: 0.3% or less W. RMS
(WS-48B)
Screw
position
L-CH
peak
within
1dB
Output
level
L-CH
peak
R-CH
peak
within
1dB
Screw
position
R-CH
peak
MAIN
board
CN301
set
test tape
P-4-A100
(10 kHz, –10 dB)
pin 1
oscilloscope
L-CH
R-CH
V
H
waveform of oscilloscope
in phase 45
° 90° 135° 180°
good
wrong
pin 2
pin 3
L
R
+
set
test tape
WS-48B 
(3 kHz, 0 dB)
main board
CN301 (Pin 
3 : L-CH)
(Pin 1 : R-CH)
frequency counter
+
set
test tape
P-4-L300
(315 Hz, 0 dB)
main board
CN301 (Pin 
: L-CH)
(Pin : R-CH)
level meter
forward
reverse
Page of 90
Display

Click on the first or last page to see other HCD-VP700 service manuals if exist.