HCD-V8800, LBT-V8800AV - Sony Audio Service Manual (repair manual). Page 16

Read Sony HCD-V8800 / LBT-V8800AV Service Manual online

— 16 —
RF PLL Free-run Frequency Check
Procedure :
1. Connect frequency counter to TP (PLCK) with lead wire.
2. Turned Power switch on.
3. Put the disc (YEDS-18) in to play the number five track.
Confirm that reading on frequency counter is 4.3218MHz.
BD board
frequency counter
TP (PLCK)
+
VIDEO SECTION
Frequency adjustment
1. Connect the frequency counter to check point of the VIDEO
board.
frequency counter
VIDEO board
TP410 (DCLK)
+
2. Adjust CT401 of the VIDEO board so that the frequency counter
read 13.5MHz ± 40Hz at STOP condition.
Adjustment Location :
[ BD BOARD ] — SIDE A —
[ VIDEO BOARD ] — SIDE B —
SL703 (AFADJ)
IC751
IC251
SL702 (ADJ)
SL701 (CAL BAR)
CT401
Frequency
TP410 (DCLK)
1
20
10
11
IC103
(RF)
(FE)
(FEI)
(TE)
(VC)
IC101
(PLCK)
Page of 89
Display