Read Sony HCD-SLK1I / HCD-SLK2I Service Manual online
HCD-SLK1i/SLK2i
5
CAPACITOR ELECTRICAL DISCHARGE PROCESSING
When checking the board, the electrical discharge is necessary for
the electric shock prevention.
Connect the resistors referring to the fi gure below.
When checking the board, the electrical discharge is necessary for
the electric shock prevention.
Connect the resistors referring to the fi gure below.
•
Switching regulator (C201, C202) (for HCD-SLK1i)
Both ends of respective capacitors.
– Switching Regulator (Conductor Side) –
T101
C202
C201
800
:/2 W
800
:/2 W
•
Switching regulator (C201) (for HCD-SLK2i)
Both ends of respective capacitor.
– Switching Regulator (Conductor Side) –
T101
C201
800
:/2 W