HCD-RG88 - Sony Audio Service Manual (repair manual). Page 21

Read Sony HCD-RG88 Service Manual online

21
HCD-RG88
CD SECTION
Note:
1.
CD Block is basically designed to operate without adjustment. Therefore,
check each item in order given.
2.
Use LUV-P01 (4-999-032-01) unless otherwise indicated.
3.
Use an oscilloscope with more than 10M
Ω impedance.
4.
Clean the object lens by an applicator with neutral detergent when the
signal level is low than specified value with the following checks.
S-CURVE  CHECK
Procedure :
1. Connect an oscilloscope to TP (FEO).
2. Connect between TP (FEI) and TP (DVC) ( 1.65 V) by lead
wire.
3. Turn the power ON.
4. Load a disc (LUV-P01) and actuate the focus search. (In
consequence of open and close the disc tray, actuate the focus
search)
5. Confirm that the oscilloscope waveform (S-curve) is
symmetrical between A and B. And confirm peak to peak level
within 2 
± 0.5 Vp-p.
6. After check, remove the lead wire connected in step 2.
Note:
• Try to measure several times to make sure than the ratio
of A : B or B : A is more than 10 : 7.
• Take sweep time as long as possible and light up the
brightness to obtain best waveform.
RF  LEVEL  CHECK
Procedure :
1. Connect an oscilloscope CH1 to TP (RFDC) and CH2 to TP
(RFAC).
2. Turn the power ON.
3. Load a disc (LUV-P01) and playback.
4. Confirm that oscilloscope waveform is clear and check if RF
signal level is correct or not.
BD board
Oscilloscope
TP(FEO)
TP(DVC)
symmetry
S-curve waveform
within 2 
±
0.5Vp-p
A
B
TP(RFDC)
TP(RFAC)
BD board
oscilloscope
TP(DVC)
Note:
Clear RF signal waveform means that the shape “ 
◊ ”  can be clearly
distinguished at the center of the waveform.
E-F BALANCE (1  TRACK  JUMP)  ADJUSTMENT
Procedure :
1. Connect an oscilloscope to TP (TEO) and TP (DVC).
2. Turn the power ON.
3. Load a disc (LUV-P01) and playback the number nine track.
4. Press the hH button. (Becomes the 1 track jump mode.)
5. Confirm that the level B and A (DC voltage) on the oscilloscope
waveform.
6. Adjust RV101 on the BD board so that the center of waveform
becomes the same voltage of DVC. (i.e.  A=0V)
Connecting and Adjustment Location: BD board
RF signal waveform
VOLT/DIV : 200mV
TIME/DIV : 500ns
level : 0.65 
±
0.15Vp-p (RFDC)
1.1 
±
0.4Vp-p (RFAC)
TP(TEO)
TP(DVC)
BD board
oscilloscope
level=1.0 
±
0.5Vp-p
symmetry
A (DC voltage)
center of
waveform
B
DVC
1 track jump waveform
Page of 74