HCD-RG88 - Sony Audio Service Manual (repair manual). Page 2

Read Sony HCD-RG88 Service Manual online

HCD-RG88
2
FM tuner section
Tuning range
87.5 – 108.0 MHz
Antenna
FM lead antenna
Antenna terminals
75 ohm unbalanced
Intermediate frequency
10.7 MHz
AM tuner section
Tuning range
Latin American models:
530 – 1,710 kHz
(with the interval set at 10
kHz)
531 – 1,710 kHz
(with the interval set at 9
kHz)
Middle Eastern models:
531 – 1,602 kHz
(with the interval set at 9
kHz)
Other models:
531 – 1,602 kHz
(with the interval set at 9
kHz)
530 – 1,710 kHz
(with the interval set at 10
kHz)
Antenna
AM loop antenna
Antenna terminals
External antenna terminal
Intermediate frequency
450 kHz
General
Power requirements
Mexican models:
120 V AC, 60 Hz
220 V AC, 50/60 Hz
Other models:
120 V, 220 V or 230 - 240
V AC, 50/60 Hz
Adjustable with voltage
selector
Power consumption
300 watts
Dimensions (w/h/d)
Approx. 280 x 360 x 445 mm
Mass :
Approx. 13.1 kg
Design and specifications are subject to change
without notice.
Argentina models:
Tuner section
FM stereo, FM/AM superheterodyne tuner
Notes on chip component replacement
• Never reuse a disconnected chip component.
• Notice that the minus side of a tantalum capacitor may be dam-
aged by heat.
Flexible Circuit Board Repairing
• Keep the temperature of the soldering iron around 270 ˚C dur-
ing repairing.
• Do not touch the soldering iron on the same conductor of the
circuit board (within 3 times).
• Be careful not to apply force on the conductor when soldering
or unsoldering.
CAUTION
Use of controls or adjustments or performance of procedures
other than those specified herein may result in hazardous ra-
diation exposure.
SAFETY-RELATED  COMPONENT  WARNING!!
COMPONENTS  IDENTIFIED  BY  MARK  
0
  OR  DOTTED
LINE  WITH  MARK  
0
  ON  THE  SCHEMATIC  DIAGRAMS
AND  IN  THE  PARTS  LIST  ARE  CRITICAL  TO  SAFE
OPERATION.  REPLACE  THESE  COMPONENTS  WITH
SONY  PARTS  WHOSE  PART  NUMBERS  APPEAR  AS
SHOWN  IN  THIS  MANUAL  OR  IN  SUPPLEMENTS  PUB-
LISHED  BY  SONY.
The following caution label is located inside the unit.
This appliance is classified as
a CLASS 1 LASER product.
The CLASS 1 LASER
PRODUCT MARKING is
located on the rear exterior.