HCD-RG80 - Sony Audio Service Manual (repair manual). Page 16

Read Sony HCD-RG80 Service Manual online

16
HCD-DX50/RG80
4. Mode:  Record
5. Mode:  Playback
6. Confirm the play back signal recorded in step 3 becomes
adjustable level as follows.
If these levels are not adjustable level, adjust the RV301 (L-
CH) and RV351 (R-CH) on the MAIN board to repeat steps 4
and 5.
Adjustable level:
CN301 PB level:  47.2 to 53.0 mV (–24.3 to –23.3 dB)
Adjustment Location:  MAIN board
[MAIN  BOARD] (Component Side)
[LEAF  SW  BOARD]  (Component Side)
REC Bias Adjustment
   DECK B
Procedure:
In the MC test mode, the “REC memory mode” is convenient for
this adjustment. In the “REC memory mode” , when the REC starts
the input signal FUNCTION is switched to VIDEO automatically.
When the REC stops, the tape returns near to the recording start
position.
1. Press  MD (VIDEO)  button to select VIDEO. (This step is not
necessary if the above test mode has already been set.)
2. Insert a tape into deck B.
3. After press  REC PAUSE/START  button, press REC PAUSE/
START button, then recording start.
4. Mode:  Record
5. Mode:  Playback
6. Confirm the playback signal recorded in step 3 becomes
adjustable level as follows.
If these levels are not adjustable level, adjust the RV304 (L-
CH) and RV354 (R-CH) on the MAIN  board to repeat steps 4
and 5.
Adjustable level: Playback output of 315 Hz to playback output
of 10 kHz:  
±1.0 dB
Adjustment Location:  MAIN board
REC Level Adjustment
   DECK B
Procedure:
In the MC test mode, the “REC memory mode” is convenient for
this adjustment. In the “REC memory mode” , when the REC starts
the input signal FUNCTION is switched to VIDEO automatically.
When the REC stops, the tape returns near to the recording start
position.
1. Press  MD (VIDEO)  button to select VIDEO. (This step is not
necessary if the above test mode has already been set.)
2. Insert a tape into deck B.
3. After press  REC PAUSE/START  button, press REC PAUSE/
START button, then recording start.
attenuator
set
MD/VIDEO (AUDIO) IN (J101)
1) 315 Hz
2) 10 kHz
50 mV (–23.8 dB)
600 
blank tape
CN-123
AF OSC
+
set
recorded
portion
CN301 (Pin 
3
: L-CH)
(Pin 
1
: R-CH)
level meter
set
MD/VIDEO (AUDIO) IN (J101) 
315 Hz, 50 mV (–23.8 dB)
blank tape
CS-123
600 
attenuator
AF OSC
+
set
recorded
portion
CN301 (Pin 
3
: L-CH)
(Pin 
1
: R-CH)
level meter
TAPE SPEED
RV1002
RV1001
(NORMAL)  (HIGH)
CN1001
T11
RV11
RV351
RV354
RV304
RV303
RV302
RV301
CN301
CN304
CN302
CN303
1
3
REC LEVEL (L)
(B)
PB LEVEL (L)
(B)
PB LEVEL (L)
(A)
REC BIAS (R)
(B)
REC BIAS (L)
(B)
REC LEVEL (R)
(B)
Page of 68