CAPACITOR ELECTRICAL DISCHARGE PROCESSING
When checking the board, the electrical discharge is necessary for the electric shock prevention.
Connect the resistors referring to the fi gure below.
When checking the board, the electrical discharge is necessary for the electric shock prevention.
Connect the resistors referring to the fi gure below.
• POWER board (C11, C12) (US and Canadian models)
Both ends of respective capacitors.
Both ends of respective capacitors.
800
:/2 W
800
:/2 W
C12
C11
– POWER Board (Conductor Side) –
• POWER board (C10) (Except US and Canadian models)
Both ends of respective capacitors.
Both ends of respective capacitors.
800
:/2 W
C10
– POWER Board (Conductor Side) –