[PROTECT KIND CHECK TEST MODE]
• This mode is used to check types of protect occurred during
• This mode is used to check types of protect occurred during
protector on.
Procedure:
1. During protection on, fl uorescent indicator tube shows
blinking message “PROTECT EXX” where “EXX” represent
the error code.
the error code.
2. Press
[ ] button & [PRESET– –] button simultaneously.
3. Fluorescent indicator tube display will toggle between
“PROTECT” message & protector kind message display.
Below table explains on protector kind.
Below table explains on protector kind.
Error
Code
Code
Protector Message
Description
E01
“AMP OCP”
The over current condition to
MOSFET occurs by defect
of MOSFET or defect of PS
output line.
MOSFET occurs by defect
of MOSFET or defect of PS
output line.
E03
“POWER SUPPLY”
Defect of power supply circuit
to AMP
to AMP
E04
“DC DETECT”
DC appears in SP terminal
by defect of AMP IC and
MOSFET.
by defect of AMP IC and
MOSFET.
E05
“THERMISTOR”
Unusual heat up of MOSFET
by improper assembly of heat
sink, destruction of MOSFET
etc.
by improper assembly of heat
sink, destruction of MOSFET
etc.
E06
“FAN BLOCK”
Defect of DC FAN and DC
FAN driver circuit
FAN driver circuit
To release from this mode:
Press [] button & [PRESET– –] button simultaneously again
or unplug & re-plug in the power cord.
Press [] button & [PRESET– –] button simultaneously again
or unplug & re-plug in the power cord.
If speaker does not have output even if the set status is not in
PROTECT mode, the following defect might be possible:
PROTECT mode, the following defect might be possible:
Defects
Possible cause
RESET defect
Reset signal status from micom is not ‘H’.
If the PROTECT mode is “POWER SUPPLY”, there is
possibility of unusual power supply of any of the AMP IC or
Pre-amplifi er.
Pre-amplifi er.
[MODEL & DEST WRITE MODE]
•
•
This mode is used to set software model & destination.
• This mode is only available when no permanent model &
destination is stored.
Procedure:
1. Press [ENTER] button & [FOOTBALL] button simultaneously
and hold for 5 seconds.
2. Fluorescent indicator tube display will show “M XXXXX”.
3. Press
3. Press
[+ PRESET+] / [PRESET– –] button to select the
model based on the set’s model.
Product Code
F. Tube display
HCD-GZX33D
“M GSXD3”
HCD-GZX55D
“M GSXD5”
HCD-GZX88D
“M GSXD8”
4. Press [ENTER] button.
5. Fluorescent indicator tube display will show “D XXXXX”.
6. Press
5. Fluorescent indicator tube display will show “D XXXXX”.
6. Press
[+ PRESET+] / [PRESET– –] button to select the
destination based on the set’s country.
Area Code
Country
F. Tube display
J1
Japan
“D J”
JE1
Tourist
“D JE”
U2/CA2
America, Canada
“D NA”
CEL/CE1/
CE2
CE2
Europe (general)
“D CE2”
CEK
U.K.
“D CEK”
RU1/RU3
Russia
“D RU”
AU1
Australia
“D AU”
CN1
China
“D CN”
E12
India, Pakistan, Morocco
“D E12”
E3/E93/
SA2/E15
SA2/E15
Middle East, Africa
(South Africa), Iran
(South Africa), Iran
“D E3”
E4
Africa
“D E12”
EA3
Saudi Arabia
“D EA3”
HK1/
HK2/PL1/
SP1/SP2/
SP6/TH1
HK2/PL1/
SP1/SP2/
SP6/TH1
Hong Kong, Philippines,
Singapore, Malaysia,
Thailand
Singapore, Malaysia,
Thailand
“D ASIA”
KR2
Korea
“D KR”
TW2
Taiwan
“D TW”
E2, E32,
E51, AR2
E51, AR2
Latin America (general),
Chile, Peru, Argentina
Chile, Peru, Argentina
“D LATIN”
BR1
Brazil
“D BR”
MX2,
MX4
MX4
Mexico
“D MX”
7. Press [ENTER] button to confi rm the selection.
8. “RESET” appears on the fl uorescent indicator tube. After that,
8. “RESET” appears on the fl uorescent indicator tube. After that,
the fl uorescent indicator tube becomes blank for a while, and
the system is reset.
the system is reset.
9. Mode in [PANEL TEST MODE] again to confi rm on the
model & destination.
Click on the first or last page to see other HCD-GZX33D / HCD-GZX55D / HCD-GZX88D service manuals if exist.