Read Sony HCD-GZR333IA Service Manual online
HCD-GZR333IA
24
To clear the Emergency History
Press the [DVD TOP MENU] button and then press the [CLEAR]
button.
The error code for all emergency history would be reset.
Press the [DVD TOP MENU] button and then press the [CLEAR]
button.
The error code for all emergency history would be reset.
Emg. History Check
1. 00 00 00 00
Laser Hours
CD
999h
59min
DVD
999h
59min
00 00 00 00
00 00 00 00
00 00 00 00
2. 00 00 00 00
00 00 00 00
00 00 00 00
00 00 00 00
Next Next Page
Prev Prev Page
O Return to Top Menu
To clear the Initialize Setup Data
Press the [DVD/TUNER MENU] button and then press the
[CLEAR] button on the remote commander.
Press the [DVD/TUNER MENU] button and then press the
[CLEAR] button on the remote commander.
Emg. History Check
Initialize setup data...
Laser Hours
CD
999h
59min
DVD
999h
59min
Next Next Page
Prev Prev Page
O Return to Top Menu
To return to the Top Menu of Remocon Diagnosis Menu
Press the [0] button on the remote commander.
Press the [0] button on the remote commander.
• Check Version Information
To check the version information, please follow the following
procedure.
procedure.
1. From the Top Menu of Remocon Diagnosis Menu, select “4.
Version information” by pressing the [4] button on the remote
commander. The following screen appears on the on-screen
display.
commander. The following screen appears on the on-screen
display.
Version information
O Return to Top Menu
Firm (Main) : Ver. xxxxx
Firm (Sub) : xxxxx
RISC : xxxxx
8032 : xxxxx
Audio DSP : xxxxx
Servo DSP : xxxxx
Firm (Sub) : xxxxx
RISC : xxxxx
8032 : xxxxx
Audio DSP : xxxxx
Servo DSP : xxxxx
To return to the Top Menu of Remocon Diagnosis Menu, press
the [0] button on the remote commander.
the [0] button on the remote commander.
SECTION 4
ELECTRICAL ADJUSTMENTS
When the optical pick-up assy is replaced, perform the “Execute
IOP Measurement”.
IOP Measurement”.
Execute IOP Measurement (See page 22)
[TEST DISC LIST]
Be sure to use the DVD disc that matches the signal standards of
your region.
• CD
Be sure to use the DVD disc that matches the signal standards of
your region.
• CD
YEDS-18 (Part No.: 3-702-101-01)
PATD-012 (Part No.: 4-225-203-01)
• DVD SL (Single Layer)
NTSC : HLX-503 (Part No.: J-6090-069-A)
HLX-504 (Part No.: J-6090-088-A)
PAL : HLX-506 (Part No.: J-6090-077-A)
• DVD DL (Double Layer)
NTSC : HLX-501 (Part No.: J-6090-071-A)
HLX-505 (Part No.: J-6090-089-A)
PAL : HLX-507 (Part No.: J-6090-078-A)
[RFMON Level Check]
Connection:
Connection:
+
–
–
CN105 pin 6 (RFMON)
CN105 pin 3 (GND)
oscilloscope
DMB19 board
Procedure:
1. Connect an oscilloscope to CN105 pin 6 (RFMON) and
1. Connect an oscilloscope to CN105 pin 6 (RFMON) and
CN105 pin 3 (GND) on the DMB19 board.
2. Turn the power on.
3. Set the test disc (refer to the TEST DISC LIST) on the tray and
3. Set the test disc (refer to the TEST DISC LIST) on the tray and
press the [
N
] button to playback.
4. Confi rm that oscilloscope waveform is clear and check RF-
MON signal level is correct or not.
Note: A clear RFMON signal waveform means that the shape “◊” can be
clearly distinguished at the center of the waveform.
RFMON signal waveform
VOLT/DIV: 200 mV
TIME/DIV: 500 nS
TIME/DIV: 500 nS
level: 0.58 ± 1.23 Vp-p (DVD)
0.57 ± 1.1 Vp-p (CD)
0.57 ± 1.1 Vp-p (CD)
DVD SECTION
Click on the first or last page to see other HCD-GZR333IA service manuals if exist.