Read Sony HCD-GX255 / HCD-RG170 / HCD-RG470 / MHC-GX255 / MHC-RG170 / MHC-RG470 Service Manual online
20
HCD-GX255/RG170/RG470
SECTION 5
ELECTRICAL ADJUSTMENTS
CD SECTION
Note:
1.
CD Block is basically designed to operate without adjustment.
Therefore, check each item in order given.
Therefore, check each item in order given.
2.
Use YEDS-18 (3-702-101-01) unless otherwise indicated.
3.
Use an oscilloscope with more than 10M
Ω impedance.
4.
Clean the object lens by an applicator with neutral detergent when the
signal level is low than specified value with the following checks.
signal level is low than specified value with the following checks.
• Abbreviation
MX: Mexican model
S-CURVE CHECK
Procedure:
1. Connect an oscilloscope to TP (FE) and TP (VC) on the CD
board (except MX) or BD board (MX).
2. Press the
I
/1
button to turn the power on.
3. Load the disc (YEDS-18) and actuate the focus search. (In
consequence of open and close the disc tray, actuate the focus
search)
search)
4. Confirm that the oscilloscope waveform (S-curve) is
symmetrical between A and B. And confirm peak to peak level
within 3
within 3
± 0.5 Vp-p.
Note:
• Try to measure several times to make sure than the ratio of A : B
or B : A is more than 10 : 7.
• Take sweep time as long as possible and light up the brightness
to obtain best waveform.
Connecting Location: CD board (except MX)
BD board (MX)
RFAC LEVEL CHECK
Procedure:
1. Connect an oscilloscope to TP (RFACO) and TP (VC) on the
CD board (except MX) or BD board (MX).
2. Press the
I
/1
button to turn the power on.
3. Load the disc (YEDS-18) and playback.
4. Confirm that oscilloscope waveform is clear and check if RFAC
4. Confirm that oscilloscope waveform is clear and check if RFAC
signal level is correct or not.
Note:
Clear RFAC signal waveform means that the shape “
◊ ” can be clearly
distinguished at the center of the waveform.
Connecting Location: CD board (except MX)
BD board (MX)
CD board (except MX)
BD board (MX)
BD board (MX)
oscilloscope
TP(FE)
TP(VC)
TP(VC)
symmetry
S-curve waveform
within 3
±
0.5 Vp-p
A
B
TP(RFACO)
CD board (except MX)
BD board (MX)
BD board (MX)
oscilloscope
TP(VC)
RF signal waveform
VOLT/DIV : 200mV
TIME/DIV : 500ns
TIME/DIV : 500ns
level : 1.3
±
0.3 Vp-p
– CD BOARD (Conductor Side) (except MX) –
– BD BOARD (Conductor Side) (MX) –
– BD BOARD (Conductor Side) (MX) –
TP
(VC)
TP
(FE)
TP
(RFACO)
IC101