Read Sony HCD-GS100 Service Manual online
22
HCD-GS100
E-F Balance Check
Connection:
Procedure:
1.
1.
Connect an oscilloscpe to test point TP (TE) and TP (DVC) on
the CD board.
the CD board.
2.
Turn the power on.
3.
Select the function “CD”.
4.
Press three buttons of
[ENTER]
,
M
, and
[REPEAT]
si-
multaneously to set the CD service mode.
5.
Put the disc (YEDS-18) in to playback the number five track.
6.
Press the
.
button. (The tracking servo and the sledding
servo are turned OFF)
7.
Check the level B of the oscilliscope's waveform and the A
(DC voltage) of the center of the Traverse waveform.
Confirm the following :
A/B x 100 = less than ± 22%
(DC voltage) of the center of the Traverse waveform.
Confirm the following :
A/B x 100 = less than ± 22%
Traverse Waveform
8.
Press the
.
button. (The tracking servo and sledding servo
are turned ON)
Confirm the C (DC voltage) is almost equal to the A (DC
voltage) is step 5.
Confirm the C (DC voltage) is almost equal to the A (DC
voltage) is step 5.
9. To exit from this mode, perform as follows.
1) Move the optical pick-up to the most inside track.
2) Press three buttons of
2) Press three buttons of
x
,
[CLEAR]
, and
[DISPLAY]
simultaneously. (cold reset)
Notes:
• Always move the optical pick-up to most inside track when
exiting from this mode. Otherwise, a disc will not be unloaded.
• Do not run the sled motor excessively, otherwise the gear can
be chipped.
Traverse Waveform
Checking Location: CD board (Conductor side)
+
–
–
CD board
TP (TE)
TP (DVC)
oscilloscope
0V
B
level: 1.15
±
0.5 Vp-p
Center of
the waveform
the waveform
A (DC
voltage)
0V
Tracking servo
Sled servo
ON
C (DC
voltage)
voltage)
Tracking servo
Sled servo
OFF
Checking Location:
– CD BOARD (Conductor Side) –
TP (VC)
TP (FE)
TP (TE)
TP
(RFDC)
TP
(DVC)
TP
(RFAC)
IC103
IC101
Click on the first or last page to see other HCD-GS100 service manuals if exist.