HCD-GRX9000, HCD-RX900, MHC-GRX9000, MHC-RX900 - Sony Audio Service Manual (repair manual). Page 14

Read Sony HCD-GRX9000 / HCD-RX900 / MHC-GRX9000 / MHC-RX900 Service Manual online

– 14 –
2. Turn the adjustment screw and check output peaks. If the peaks
do not match for L-CH and R-CH, turn the adjustment screw
so that outputs match within 1dB of peak.
3. Mode:  Playback (FWD)
4. Repeat setps 1 to 3 in playback (REV) mode.
5. After the adjustments, apply suitable locking compound to the
pats adjusted.
Adjustment Location: Playback Head (Deck A).
 Record/Playback/Erase Head (Deck B).
Tape Speed Adjustment
DECK B
Note:
Start the Tape Speed adjustment as below after setting to the test
mode.
In the test mode, the tape speed is high during pressing the
[HI-DUB]
 button.
Procedure:
1. Turn the power switch on.
2. Press the
p button, 
[ENTER/NEXT]
 button and 
[DISC 3]
 button
simultaneously.
(The “VOLUME” on the fluorescent indicator tube will blink
while in the test mode.)
To exit from the test mode, press the
I/
u
button.
Mode:  Playback
1. Insert the WS-48B into the deck B.
2. Press the
· button on the deck B.
3. Press the 
[HI-DUB]
 button in playback mode.
Then at HIGH speed mode.
4. Adjust RV1001 on the LEAF SW board do that frequency
counter reads 6,000 ± 180 Hz.
5. Press the 
[HI-DUB]
 button.
Then back to NORMAL speed mode.
6. Adjust RV1002 on the LEAF SW board so that frequency
counter reads 3,000 ± 90 Hz.
Adjustment Location:  LEAF SW board
Sample value of Wow and Flutter: 0.3% or less W.RMS (JIS)
(WS-48B)
Playback level Adjustment
DECK A
DECK B
Procedure:
Mode:  Playback
Deck A is RV311 (L-CH) and RV411 (R-CH), Deck B is RV301
(L-CH) and RV401 (R-CH) so that adjustment within adjustment
level as follows.
Adjustment Level:
CN301 PB level:  301.5 to 338.3 mV (–8.2 to  –7.2 dB) level
difference between the channels: within ± 0.5 dB
Adjustment Location:  AUDIO board
Screw
position
L-CH
peak
within
1dB
Output
level
L-CH
peak
R-CH
peak
within
1dB
Screw
position
R-CH
peak
set
test tape
P-4-A100
(10 kHz, –10 dB)
(pin 
1
: R-CH)
oscilloscope
V
H
waveform of oscilloscope
in phase 45 
°
90 
°
135 
°
180 
°
good
wrong
(pin 
2
: GND)
(pin 
3
: L-CH)
MAIN board
CN301
+
set
test tape
WS-48B 
(3 kHz, 0 dB)
MAIN board
CN301 (Pin 
3
 : L-CH)
(Pin 
1
 : R-CH)
frequency counter
+
set
test tape
P-4-L300
(315 Hz, 0 dB)
MAIN board
CN301 (Pin 
3
: L-CH)
(Pin 
1
: R-CH)
level meter
forward
reverse
Page of 86
Display