HCD-GR5, HCD-RX50, MHC-GR5, MHC-RX50 - Sony Audio Service Manual (repair manual). Page 13

Read Sony HCD-GR5 / HCD-RX50 / MHC-GR5 / MHC-RX50 Service Manual online

— 13 —
Record Level Adjustment  (Deck B)
Procedure:
1. Press  FUNCTION  button to Select MD.
2. Mode: Record
blank tape
CS-123
Record Bias Adjustment  (Deck B)
Procedure:
1. Press  FUNCTION  button to Select MD.
2. Mode: Record
4. Confirm playback the signal recorded in step 2 become
adjustment level as follows.
If these levels do not adjustment level, adjust the RV341 (L-CH)
and RV441 (R-CH) on the AUDIO board to repeat steps 2 and 3.
Adjustment level: The playback output of 10 kHz level difference
against 315 Hz reference should be ± 0.5 dB.
Adjustment Location: AUDIO board
MD IN
1) 315Hz
2) 10kHz
}
 50 mV (–23.8 dB)
AF OSC
attenuator
600 
blank tape
CS-123
set
MAIN board
CN403
Pin 
3
 (L-CH)
Pin 
1
 (R-CH)
level meter
recorded
position
set
3. Mode: Playback
Adjustment Location:
[AUDIO BOARD] 
(Conductor Side)
MD IN
315Hz 50mV (–23.8 dB)
AF OSC
attenuator
600 
set
3. Mode: Playback
recorded
portion
set
MAIN board
CN403
Pin 
3
 (L-CH)
Pin 
1
 (R-CH)
4. Confirm playback the signal recorded in step 2 become
adjustment level as follows.
If these levels do not adjustment level, adjust the RV301 (L-CH)
and RV351 (R-CH) on the MAIN board to repeat steps 2 and 3.
Adjustment level:
CN403 PB level: 47.3 to 53.1 mV (–24.3 to –23.3 dB)
Adjustment Location: MAIN board
RV301
IC401
1 3
CN403
RV351
RV351
Record Level Adjustment
(R CH)
RV301
Record Level Adjustment
(L CH)
RV341 (L CH), 441 (R CH)
Record Bias Adjustment
RV301
RV401
RV341
RV651
RV652
RV311
RV411
RV301 (L CH), 401(R CH)
Playback Level Adjustment
(Deck B)
RV441
RV311 (L CH), 411 (R CH)
Playback Level Adjustment
(Deck A)
level meter
RV651 (Normal speed)
RV652 (High speed)
Tape Speed Adjustment
[MAIN BOARD] (Component Side)
Page of 57
Display

Click on the first or last page to see other HCD-GR5 / HCD-RX50 / MHC-GR5 / MHC-RX50 service manuals if exist.