HCD-GNZ7D, HCD-GNZ8D, HCD-GNZ9D, MHC-GNZ7D, MHC-GNZ8D, MHC-GNZ9D - Sony Audio Service Manual (repair manual). Page 26

Read Sony HCD-GNZ7D / HCD-GNZ8D / HCD-GNZ9D / MHC-GNZ7D / MHC-GNZ8D / MHC-GNZ9D Service Manual online

26
HCD-GNZ7D/GNZ8D/GNZ9D
SECTION 6
ELECTRICAL ADJUSTMENTS
VIDEO  SECTION
Video Level Check (VIDEO BOARD)
Purpose
This adjustment is made to satisfy the NTSC standard, and if not
adjusted correctly, the brightness will be too large or small.
Procedure:
1. Connect oscilloscope to VIDEO output.
2. Load a DVD reference disc playback.
3. Check the video signal level is 1.00±0.07Vp-p.
DVD SECTION
When the base unit is replaced, perform the adjustment and the
measurement as shown below in this order.
1) MIRROR TIME ADJUSTMENT (See page 22)
2) EXECUTING IOP MEASUREMENT (See page 24)
[TEST DISC LIST]
Be sure to use the DVD disc that matches the signal standards of
your region.
• CD
YEDS-18 (Part No.: 3-702-101-01)
PATD-012 (Part No.: 4-225-203-01)
• DVD SL (Single Layer)
    NTSC : HLX-503 (Part No.: J-6090-069-A)
HLX-504 (Part No.: J-6090-088-A)
    PAL
: HLX-506 (Part No.: J-6090-077-A)
• DVD DL (Dual Layer)
    NTSC : HLX-501 (Part No.: J-6090-071-A)
HLX-505 (Part No.: J-6090-089-A)
    PAL
: HLX-507 (Part No.: J-6090-078-A)
[RFMON Level Check]
Connection:
Procedure:
1. Connect an oscilloscope to CN105 pin 6  (RFMON) and
CN105 pin 3 (GND) on the DMB10 board.
2. Turn the power on.
3. Set the test disc (refer to the TEST DISC LIST) on the tray
and press  H  button to playback.
4. Confirm that oscilloscope waveform is clear and check
RFMON signal level is correct or not.
Note:
A clear RFMON signal waveform means that the shape “
◊” can be
clearly distinguished at the center of the waveform.
Checking Location: DMB10 board (Side A)
+
CN105 pin 
6
 (RFMON)
CN105 pin 
3
 (GND)
oscilloscope 
DMB10 board
VOLT/DIV: 200 mV
TIME/DIV: 500 ns
RFMON signal waveform
level: 0.58 
±
 1.23 Vp-p (DVD)
          0.57 
±
 1.1 Vp-p (CD)
IC102
IC101
IC104
IC201
CN105
CN106
CN105 pin 
3
 (GND)
CN105 pin 
6
 (RFMON)
1
6
oscilloscope
set
J802
VIDEO OUTPUT
75 
1.00 
±
 0.07 Vp-p
(WHITE 100%)
Ver. 1.1
Page of 104