HCD-F250AV, MHC-F250AV - Sony Audio Service Manual (repair manual). Page 18

Read Sony HCD-F250AV / MHC-F250AV Service Manual online

— 18 —
SECTION  4
MECHANICAL  ADJUSTMENT
 TAPE MECHANISM DECK SECTION
• Torque  Measurement
 CD MECHANISM DECK SECTION
To adjust the mechanism section, enter the mechanism section adjustment mode.
For how to enter the mechanism section adjustment mode, refer to each adjustment section.
DISC SENSOR ALIGMENT
1. Make sure that there is no disc in the unit.
2. Connect an oscilloscope to IC401
$™, IC4024 of the MAIN board.
3. Turn the power switch on.
Precaution
1. Clean the following parts with a denatured alcohol-moistened
swab:
record/playback heads
pinch rollers
erase head
rubber belts
capstan
idlers
2. Demagnetize the record/playback head with a head
demagnetizer.
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
5. The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
31 to 71 g • cm
(0.43 – 0.98 oz • inch)
2 to 6 g • cm
(0.02 – 0.08 oz • inch)
31 to 71 g • cm
(0.43 – 0.98 oz • inch)
2 to 6 g • cm
(0.02 – 0.08 oz • inch)
71 to 143 g • cm
(0.98 – 1.99 oz • inch)
100 g or more
(3.53 oz or more)
100 g or more
(3.53 oz or more)
Mode
FWD
Torque meter
CQ-102C
Meter reading
FWD
back tension
REV
REV
back tension
FF/REW
FWD tension
REV tension
CQ-102C
CQ-102RC
CQ-102RC
CQ-201B
CQ-403A
CQ-403R
4. Press the  
p
  button,  ENTER  button and  GROUP 5  button simultaneously.
oscilloscope
IC401
$™
 D.SENS (CH1)
IC401
4
HHOUT (CH2)
GND
Page of 82
Display