HCD-EC599, MHC-EC599 - Sony Audio Service Manual (repair manual). Page 11

Read Sony HCD-EC599 / MHC-EC599 Service Manual online

HCD-EC599
11
3.  Press three buttons of [u], [
-
] and [
?/1
] simultaneously.
4.  It enters the CD factory mode and the message “FACTORY” is 
displayed. When the [OPTIONS] button is pressed, the follow-
ing message (initial display) is displayed.
  – ON   
 
 
S character mode setting
 
 
Tracking servo setting
 
 RF gain setting
Key Operation:
[OPTIONS]:
 
The display changes in the following order when-
ever the button is pressed.
 
[DSGX]:
 
RF gain setting changes whenever the button is 
pressed.
 
“–”: No gain fi xation.
 
“AL”: Fix to the gain for AL disc.
 
“RW”: Fix to the gain for RW disc.
[FUNCTION]:
 
S character mode setting changes whenever the but-
ton is pressed.
 
“  ”: S character mode OFF.
 
“S”: S character mode ON.
5.  To release from this mode, Press three buttons of [u], [
-
]
and [
?/1
] simultaneously.
PROTECT KIND CHECK TEST MODE
This mode is used to check types of protect occurred during 
protector on.
Procedure:
During protection on, LCD will toggle between “PROTECT” 
message & type of protection mode.
Indication of LCD
Type of defect
Possible cause(s)
PROTECT E01
Defect of AMP 
circuit
Defect of IC701, '+' 
and '-' speaker cord are 
shorted, fan is blocked 
from turning
PROTECT E02
Defect of power 
supply circuit 
to CD
Defect of optical unit, 
transformer or 9V 
Regulator supply
PROTECT E03
Defect of 
USB+5V power 
supply
Defect of IC400 and 
related circuitry
PROTECT E04
Defect of 9V 
power supply
Unusual heat up of 
IC702 (9V regulator) 
by improper assembly 
of heatsink, destruction 
of IC702 etc..
PROTECT E05
AC supply 
mismatch
Incorrect voltage 
selector setting
(Initial display)
FCSAG**(**: Focus AGC value)
TRKAG**(**: Track AGC value)
RF_AG**(**: RF AGC value)
Page of 46
Display

Click on the first or last page to see other HCD-EC599 / MHC-EC599 service manuals if exist.