HCD-E800W - Sony Audio Service Manual (repair manual). Page 14

Read Sony HCD-E800W Service Manual online

HCD-E800W
14
SECTION  3
TEST  MODE
1.  TEST  MODES  OTHER  THAN  THE  TEST  MENU
These are executable test mode even if not entering the test menu.
1-1. Cold Reset
The cold reset clears data except BD/DVD data stored in the RAM 
to initial conditions. Execute this mode when returning the set to 
the customers.
Procedure:
1.  Press the [
?/1
] button to turn the power on.
2.  Press the [
x
], [VOLUME –] and [
Z
] buttons simultaneously 
and hold down (around 5 seconds).
3.  The message “COLD RESET” appears on fl uorescent indica-
tor tube, then becomes standby states.
1-2.  Disc Tray Lock
This mode let you lock the disc tray. When this mode is activated, 
the disc will not eject when the [
Z
] button is pressed. The message 
“LOCKED” will be displayed on the fluorescent indicator tube.
Procedure:
1.  Press the [
?/1
] button to turn the power on. 
2.  Press the [FUNCTION] button to select the “BD/DVD”.
3.  Press the [
x
] and [
Z
] buttons simultaneously and hold down 
until “LOCKED” or “UNLOCKED” displayed on the fluores-
cent indicator tube (around 5 seconds).
2.  TEST  MODES  IN  THE  TEST  MENU
These are the test modes done in the test menu.
Setting method of the test menu:
1.  Press the [
?/1
] button to turn the power on.
2.  Press button in order of the [CLEAR] 
→ [
3
→ [0] → [1] → 
[0] 
→ [ANGLE] on the remote commander (Make the interval 
when each button is pressed within two seconds).
3.  The message “TEST MENU” appears on the fluorescent indi-
cator tube and enter the test menu.
2-1. Panel Test
Procedure:
1.  Enter the test menu.
2. Press the [
M
]/[
m
] buttons on the remote commander to select 
the “PANEL TEST”, and press the [
3
] button on the remote 
commander.
3.  LEDs and all segments in fl uorescent indicator tube are lighted 
up. And half segments in fl uorescent indicator tube are lighted 
up, others half segments in fl uorescent indicator tube are light-
ed up, then LEDs and all segments in fl uorescent indicator tube 
are lighted up. This operation is repeated.
4.  When all segments in fl uorescent indicator tube are lighted up 
in the state of step 3, press the [VOLUME +] button on the 
remote commander and model information is displayed on the 
fl uorescent indicator tube.
 
Each time the [VOLUME +] button on the remote commander 
is pressed, the display changes from destination information, 
MC version, SYS version, UI version, DVD version, ST ver-
sion, TA version, DSP version, TM version, CLA version, CEC 
version, SAIR version, DSPF version in this order, and returns 
to the model information display.
 
Each time the [VOLUME –] button on the remote commander 
is pressed, the version and date are switched.
5.  In the state of step 3, press the [FUNCTION] button on the 
remote commander and “K 0” is displayed on the fluorescent 
indicator tube.
 
“K 0” value increases whenever a button on the set is pressed 
or a sensor is touched. However, once a button has been 
pressed, it is no longed taken into account.
 
All buttons on the set are pressed and all sensors are touched, 
“OK” and “K 7” are alternately displayed on the fluorescent 
indicator tube.
6.  To release from this mode, press the [
?/1
] button.
2-2. AMP Test
Procedure:
1.  Enter the test menu.
2. Press the [
M
]/[
m
] buttons on the remote commander to select 
the “AMP TEST”, and press the [
3
] button on the remote 
commander.
3.  The message “MEASURE” appears on the fluorescent indica-
tor tube and enter the AMP test mode.
4.   Press the [BLUE] button on the remote commander, the state 
of D.C.A.C. microphone is displayed on the fl uorescent indica-
tor tube.
 
“D.C.A.C M. IN”  : D.C.A.C. microphone on (Microphone 
detection)
 
“D.C.A.C M. OUT” : D.C.A.C. microphone on (Microphone 
non-detection)
 
“FUNC INPUT” 
: D.C.A.C. microphone off
5.   Press the [MUTING] button on the remote commander, “VOL-
UME MIN/NORMAL/MAX” can be switched.
6.   Press the [SUBTITLE] button on the remote commander, the 
message “VACS ON” or “VACS OFF” appears on the fl uores-
cent indicator tube and thus the VACS on/off are changed.
7.   To release from this mode, press the [
?/1
] button.