Read Sony HCD-D90AV / HCD-GR10AV / HCD-RX100AV / MHC-D90AV / MHC-GR10AV / MHC-RX100AV Service Manual online
— 14 —
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
Adjustment Location: Playback Head (Deck A)
Record/Playback/Erase Head (Deck B)
4 5 ˚
9 0 ˚
135˚
180˚
wrong
good
in phase
Waveform of oscilloscope
output
level
level
L-CH
peak
peak
screw
position
position
R-CH
peak
peak
within
1dB
1dB
within 1dB
L-CH
peak
peak
R-CH
peak
peak
screw
position
position
2. Turn the adjustment screw and check output peaks. If the peaks
do not match for L-CH and R-CH, turn the adjustment screw so
that outputs match within 1 dB of peak.
that outputs match within 1 dB of peak.
3. Mode: Playback
R
set
test tape
P-4-A100
(10kHz, –10dB)
P-4-A100
(10kHz, –10dB)
main board
CN403
Pin
CN403
Pin
3
(L-CH)
oscilloscope
Pin
2
(GND)
L
Pin
1
(R-CH)
Tape Speed Adjustment (Deck A)
Note: Set the test mode using the following method and begin tape
speed adjustment.
In the test mode, the tape will move at double speed while
the HIGH SPEED DUBBING button is pressed.
In the test mode, the tape will move at double speed while
the HIGH SPEED DUBBING button is pressed.
Procedure:
With the power turned ON, press the SPECTRUM ANALYZER
button, ENTER/NEXT button, and EFFECT ON/OFF button
simultaneously.
(The “VOLUME” on the fluorescent display tube will blink while
in the test mode.)
To exit the test mode, press the POWER button.
With the power turned ON, press the SPECTRUM ANALYZER
button, ENTER/NEXT button, and EFFECT ON/OFF button
simultaneously.
(The “VOLUME” on the fluorescent display tube will blink while
in the test mode.)
To exit the test mode, press the POWER button.
1. Load WS-48B into deck A and a recordable tape into deck B.
2. Press the
2. Press the
r REC button, and press the · button of deck B to
set deck B into the recording state.
3. Play deck A.
4. While pressing the HIGH SPEED DUBBING button, set double
4. While pressing the HIGH SPEED DUBBING button, set double
speed play.
5. Adjust RV652 of the AUDIO board so that the reading of the
frequency counter becomes 6000 ± 30 Hz.
6. Release the HIGH SPEED DUBBING button to set normal
speed play.
7. Adjust RV651 of the AUDIO board so that the reading of the
frequency counter becomes 3000 ± 15 Hz.
Adjustment Location: AUDIO board
Playback Level Adjustment (Deck A, Deck B)
Procedure:
Mode: Playback
Mode: Playback
set
test tape P-4-L300
(315Hz, 0dB)
(315Hz, 0dB)
main board
CN403 Pin
CN403 Pin
3
(L-CH)
Pin
1
(R-CH)
level meter
Deck A is RV311 (L-CH) and RV411 (R-CH), deck B is RV301
(L-CH) and RV401 (R-CH)
so that adjustment within the following adjustment level.
(L-CH) and RV401 (R-CH)
so that adjustment within the following adjustment level.
Adjustment level:
CN403 playback level: 301.5 to 338.3 mV (–8.2 to –7.2 dB)
level difference between the channels: within ± 0.5 dB
Adjustment Location: AUDIO board
CN403 playback level: 301.5 to 338.3 mV (–8.2 to –7.2 dB)
level difference between the channels: within ± 0.5 dB
Adjustment Location: AUDIO board
foward
reverse
Click on the first or last page to see other HCD-D90AV / HCD-GR10AV / HCD-RX100AV / MHC-D90AV / MHC-GR10AV / MHC-RX100AV service manuals if exist.