HCD-CP300 - Sony Audio Service Manual (repair manual). Page 3

Read Sony HCD-CP300 Service Manual online

3
HCD-CP300
SAFETY-RELATED COMPONENT WARNING!!
COMPONENTS IDENTIFIED BY MARK 
0
 OR DOTTED LINE WITH
MARK 
0
 ON THE SCHEMATIC DIAGRAMS AND IN THE PARTS
LIST ARE CRITICAL TO SAFE OPERATION. REPLACE THESE
COMPONENTS WITH SONY PARTS WHOSE PART NUMBERS
APPEAR AS SHOWN IN THIS MANUAL OR IN SUPPLEMENTS
PUBLISHED BY SONY.
ATTENTION AU COMPOSANT AYANT RAPPORT
À LA SÉCURITÉ!
LES COMPOSANTS IDENTIFÉS PAR UNE MARQUE 
0
 SUR LES
DIAGRAMMES SCHÉMATIQUES ET LA LISTE DES PIÈCES SONT
CRITIQUES POUR LA SÉCURITÉ DE FONCTIONNEMENT. NE
REMPLACER CES COMPOSANTS QUE PAR DES PIÈSES SONY
DONT LES NUMÉROS SONT DONNÉS DANS CE MANUEL OU
DANS LES SUPPÉMENTS PUBLIÉS PAR SONY.
CAUTION
Use of controls or adjustments or performance of procedures
other than those specified herein may result in hazardous
radiation exposure.
This appliance is classified as a CLASS 1 LASER product.
The CLASS 1 LASER PRODUCT MARKING is located on
the rear exterior.
Laser component in this product is capable of emitting radiation
exceeding the limit for Class 1.
The following caution label is located inside the unit.
CAUTION
:
INVISIBLE    LASER    RADIATION    WHEN    OPEN    AND
INTERLOCKS   DEFEATED.    AVOID   EXPOSURE   TO   BEAM.
ADVARSEL :
USYNLIG   LASERSTRÅLING   VED   ÅBNING   NÅR 
SIKKERHEDSAFBRYDERE  ER  UDE  AF  FUNKTION.   UNDGÅ  UDSAETTELSE 
FOR  STRÅLING.
VORSICHT :
UNSICHTBARE  LASERSTRAHLUNG,  WENN 
ABDECKUNG  GEÖFFNET  UND  SICHEREITSVERRIEGELUNG 
ÜBERBRÜCKT.  NICHT  DEM  STRAHL  AUSSETZEN.
VARO
!
:
AVATTAESSA JA SUOJALUKITUS OHITETTAESSA OLET ALT-
TIINA  NÄKYMÄTTÖMÄLLE  LASERSÄTEILYLLE.  ÄLÄ  KATSO  SÄTEESEEN.
VARNING
:
OSYNLING LASERSTRÅLING NÄR DENNA  DEL ÄR ÖPPNAD
OCH SPÄRREN ÄR URKOPPLAD. BETRAKTA EJ STRÅLEN.
ADVERSEL :
USYNLIG  LASERSTRÅLING  NÅR  DEKSEL  ÅPNES  OG 
SIKKERHEDSLÅS BRYTES.  UNNGÅ EKSPONERING FOR STRÅLEN.
VIGYAZAT
! :
A  BURKOLAT  NYITÁSAKOR  LÁTHATATLAN  LÉZERSU-
GÁRVESZÉLY
!   KERÜLJE  A  BESUGÁRZÁST! 
Notes on chip component replacement
• Never reuse a disconnected chip component.
• Notice that the minus side of a tantalum capacitor may be dam-
aged by heat.
Flexible Circuit Board Repairing
• Keep the temperature of the soldering iron around 270 ˚C dur-
ing repairing.
• Do not touch the soldering iron on the same conductor of the
circuit board (within 3 times).
• Be careful not to apply force on the conductor when soldering
or unsoldering.
SAFETY  CHECK-OUT
After correcting the original service problem, perform the following
safety check before releasing the set to the customer:
Check the antenna terminals, metal trim, “metallized” knobs, screws,
and all other exposed metal parts for AC leakage.
Check leakage as described below.
LEAKAGE  TEST
The AC leakage from any exposed metal part to earth ground and
from all exposed metal parts to any exposed metal part having a
return to chassis, must not exceed 0.5 mA (500 microamperes.).
Leakage current can be measured by any one of three methods.
1.
A commercial leakage tester, such as the Simpson 229 or
RCA WT-540A. Follow the manufacturers’ instructions to use
these instruments.
2.
A battery-operated AC milliammeter. The Data Precision
245 digital multimeter is suitable for this job.
3.
Measuring the voltage drop across a resistor by means of a
VOM or battery-operated AC voltmeter. The “limit” indication
is 0.75 V, so analog meters must have an accurate low-voltage
scale. The Simpson 250 and Sanwa SH-63Trd are examples of
a passive VOM that is suitable. Nearly all battery operated digital
multimeters that have a 2 V AC range are suitable.  (See Fig. A)
Fig. A.
Using an AC voltmeter to check AC leakage.
1.5 k
0.15 
µ
F
AC
voltmeter
(0.75 V)
To Exposed Metal
Parts on Set
Earth Ground
Page of 55