HCD-CP100, HCD-CP100K - Sony Audio Service Manual (repair manual). Page 13

Read Sony HCD-CP100 / HCD-CP100K Service Manual online

HCD-CP100/CP100K
13
13
2.
Turn the adjustment screw and check output peaks. If the peaks
do not match for L-CH and R-CH, turn the adjustment screw
so that outputs match within 1dB of peak.
3.
Mode: Playback
4.
Repeat step 1 to 3 in playback (REV) mode.
5.
After the adjustments, apply suitable locking compound to the
pats adjusted.
Adjustment Location:
SECTION  5
ELECTRICAL  ADJUSTMENTS
0 dB=0.775 V
DECK  SECTION
Tape
Signal
Used for
P-4-A100
10 kHz, –10 dB
Azimuth Adjustment
WS-48B
3 kHz, 0 dB
Tape Speed Adjustment
P-4-L300
315 Hz, 0 dB
Level Adjustment
Note:
Confirm each contents of this section first of all. If the results are
not satisfied, do the adjustment.
1.
Demagnetize the record/playback head with a head
demagnetizer.
2.
Do not use a magnetized screwdriver for the adjustments.
3.
After the adjustments, apply suitable locking compound to the
parts adjust.
4.
The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
5.
The adjustments should be performed in the order given in this
service manual.  (As a general rule, playback circuit adjustment
should be completed before performing recording circuit
adjustment.)
6.
The adjustments should be performed for both L-CH and R-
CH.
7.
Switches and controls should be set as follows unless otherwise
specified.
• Test Tape
Record/Playback Head Azimuth Adjustment
Procedure:
1.
Mode:  Playback
set
MAIN board
SPEAKER terminals (SJ301)
L-CH, R-CH
+
level meter
test tape
P-4-A100
(10 kHz, –10 dB)
Screw
position
L-CH
peak
within
1 dB
Output
level
L-CH
peak
R-CH
peak
within
1 dB
Screw
position
R-CH
peak
MAIN
board
CN301
set
test tape
P-4-A100
(10 kHz, –10 dB)
R-CH
oscilloscope
L-CH
R-CH
V
H
waveform of oscilloscope
in phase 45
°
90
°
135
°
180
°
good
wrong
MAIN board
SPEAKER terminals (SJ301)
L-CH
forward
reverse
IC103
TP (RF)
TP (VC)
CD SECTION
Note:
1.
CD Block is basically constructed to operate without
adjustment.
2.
Use YEDS-18 disc (3-702-101-01) unless otherwise indicated.
3.
Use an oscilloscope with more than 10 M
 impedance.
4.
Clean the object lens by an applicator with neutral detergent
when the signal level is low than specified value with the
following checks.
5.
Check the focus bias check when optical block is replaced.
Focus Bias Check
Procedure :
1.
Connect oscilloscope to TP (RF) and TP (VC) on the CD board.
2.
Press the
I/1
button to turn the power on, and press the
Z
(CD) button to open the CD disc tray.
3.
Put disc (YEDS-18) in and press the
u
(CD) button to play-
back.
4.
Confirm that oscilloscope waveform is as shown in the figure
below. (eye pattern)
A good eye pattern means that the diamond shape ( 
 
) in the
center of the waveform can be clearly distinguished.
+
BD board
TP (RF)
TP (VC)
oscilloscope
(DC range)
VOLT/DIV: 200 mV
TIME/DIV: 500 ns
level:
1.2 
±
 0.1 Vp-p
s
Checking Location:
– CD  BOARD (Conductor Side) –
Page of 49