HCD-BX6AV, HCD-DX6AV, MHC-BX6AV, MHC-DX6AV - Sony Audio Service Manual (repair manual). Page 3

Read Sony HCD-BX6AV / HCD-DX6AV / MHC-BX6AV / MHC-DX6AV Service Manual online

3
SECTION  1
SERVICING  NOTES
The laser diode in the optical pick-up block may suffer electro-
static break-down because of the potential difference generated
by the charged electrostatic load, etc. on clothing and the human
body.
During repair, pay attention to electrostatic break-down and also
use the procedure in the printed matter which is included in the
repair parts.
The flexible board is easily damaged and should be handled with
care.
NOTES  ON  LASER  DIODE  EMISSION  CHECK
The laser beam on this model is concentrated so as to be focused
on the disc reflective surface by the objective lens in the optical
pick-up block. Therefore, when checking the laser diode emis-
sion, observe from more than 30 cm away from the objective lens.
• MODEL IDENTIFICATION
– Rear Panel –
NOTES  ON  HANDLING  THE  OPTICAL  PICK-UP
BLOCK  OR  BASE  UNIT
Model
Power Voltage Indication
US model
AC: 120 V - 60 Hz 160 W
Canadian model
AC: 120 V - 60 Hz 180 W
AEP, UK models
AC: 230 V - 50/60 Hz 160 W
Australian model
AC: 220 – 240 V - 50/60 Hz 160 W
Mexican model
AC: 120 V - 50/60 Hz 160 W
Other models
AC: 110 – 120 V/220 – 240 V - 50/60 Hz 160 W
Power Voltage Indication
SAFETY  CHECK-OUT
After correcting the original service problem, perform the follow-
ing safety check before releasing the set to the customer:
Check the antenna terminals, metal trim, “metallized” knobs,
screws, and all other exposed metal parts for AC leakage.
Check leakage as described below.
LEAKAGE  TEST
The AC leakage from any exposed metal part to earth ground and
from all exposed metal parts to any exposed metal part having a
return to chassis, must not exceed 0.5 mA (500 microamperes.).
Leakage current can be measured by any one of three methods.
1. A commercial leakage tester, such as the Simpson 229 or RCA
WT-540A. Follow the manufacturers’ instructions to use these
instruments.
2. A battery-operated AC milliammeter. The Data Precision 245
digital multimeter is suitable for this job.
3. Measuring the voltage drop across a resistor by means of a
VOM or battery-operated AC voltmeter. The “limit” indica-
tion is 0.75 V, so analog meters must have an accurate low-
voltage scale. The Simpson 250 and Sanwa SH-63Trd are ex-
amples of a passive VOM that is suitable. Nearly all battery
operated digital multimeters that have a 2 V AC range are suit-
able.  (See Fig. A)
Fig. A.
Using an AC voltmeter to check AC leakage.
1.5 k
0.15 
µ
F
AC
voltmeter
(0.75 V)
To Exposed Metal
Parts on Set
Earth Ground
The following caution label is located inside the unit.
Page of 53
Display

Click on the first or last page to see other HCD-BX6AV / HCD-DX6AV / MHC-BX6AV / MHC-DX6AV service manuals if exist.