DHC-MD515, HCD-MD515, RM-MD515 - Sony Audio Service Manual (repair manual). Page 18

Read Sony DHC-MD515 / HCD-MD515 / RM-MD515 Service Manual online

– 18 –
CD  BASE  UNIT  (BU-5BD29)
5
Remove the CD base unit (BU-5BD29)
to direction of the arrow.
2
two screws
(BV3 
×
 8)
4
four screws
(BV3 
×
 8)
1
connector
(CN691)
3
CDM board
1
three connectors
(CN692, 693, 694)
OPTICAL  PICK-UP  CLEANING
applicator
optical pick-up
Note 1:
In cleaning the lens, do not apply an excessive force.
As the optical pick-up is vulnerable, application of
excessive force could damage the lens holder.
Note 2:
In cleaning, do not use a cleaner other than exclusive cleaning
liquid (KK-91 or isopropyl alcohol).
Note 3:
Wipe the objective lens spirally from center toward outside.
(See Figure A)
(Figure A)