DISC  TABLE  GETTING  OUT  PROCEDURE  ON
THE  POWER  SUPPLY  IS  OFF
1. Insert the tweezers to a hole on bottom of the chassis as shown
a figure, then tern fully it toward direction 2.
2. Pull out the disc table.
disc table
cam
1
 tweezers
2
3
FLUORESCENT  INDICATOR  TUBE/BUTTONS/JOG/
LEDs  CHECK  MODE
1. Press two buttons PLAY MODE and
p (MD) simultaneously
for standby status.
2. Fluorescent indicator tube and LEDs are all turned on.
Press FUNCTION button, the fluorescent indicator tube dis-
plays pattern change to cycle.
Turning the VOLUME knob, and the each LED turned on to
order.
3. Press
p (CD) button, and the Key check mode.
4. The fluorescent indicator tube displays “KEY=0  JOG=0”.
Each time a button is pressed, “KEY”=value increases.
Howerer, once a button is pressed, it is no longer taken into
account.
“JOG=” value increases like 1, 2, 3... if rotating VOLUME
knob in clock width, or it decreases like 0, 9, 8... if rotating in
cunter clock width.
5. To exit from this mode, press order all buttons (15 buttons), the
displays “KEY=OK”, and press any button, or disconnect the
power cord.
SUB  CLOCK  CHECK
1. Connect an oscilloscope to IC601 pin (¡ and ground of the
MAIN board.
2. Press two buttons PLAY MODE and
§ (MD)
Simultaneously, and the fluorescent indicator tube displays
“32.768 kHz (91)”.
3. To check the signal on oscilloscope becomes 32 kHz square
wave.
4. Press POWER button to exit.
TA  CHECK
1. Press POWER button and system power on.
2. Press two buttons PLAY MODE and
p (CD)
simultaneously, the fluorescent indicator tube displays “TA
Test”.
3. Rotation VOLUME knob in clock width a little, the fluores-
cent indicator tube displays “Volume MAX”.
Rotation VOLUME knob in cunter clock widh a little, the fluo-
rescent indicator tube displays “Volume MIN”.
4. Press CD-MD SYNC button, the fluorescent indicator tube
displays “BASS/TRE MAX”. Press REPEAT button, the fluo-
rescent indicator tube displays “BASS/TRE MIN”. Press
p (MD) button, the fluorescent indicator tube displays “ALL
FLAT”. Press
p (CD) button, the fluorescent indicator tube
displays “SURROUND = ON”.
5. Press POWER button to exit, and system power off.