Read Sony DAV-SZ1000W / HBD-SZ1000W (serv.man2) Service Manual online
1. The power is not turned on.
1. Make sure the AC power code is connected properly.
2. When connecting the AC power code into an outlet for the first time, the unit
automatically enters to STANDBY mode Check the unit at this stage “DMEO”
automatically enters to STANDBY mode. Check the unit at this stage, DMEO
indication is shown on the display. If the unit dose not work, firstly check the
status of the SYSTEM CONTROLLER(IC5002) to boot up, for voltage and clock
generation and such.
indication is shown on the display. If the unit dose not work, firstly check the
status of the SYSTEM CONTROLLER(IC5002) to boot up, for voltage and clock
generation and such.
3. Check if the VDR901 is not cut.
2. The System dose not work normally
1. Pull out the AC power code form the outlet and then reconnect after several
minutes.
2. Perform the following steps to reset.
1. Press the power button to turn it on.
2. Press “PLAY”, “FUNCTION”, and POWER button at same time. “RESET”
appears in the front panel display.
(Note)
•
When resetting, the [MEDIA], [INTERVAL], and [EFFECT] configuration setting
i iti li
d
31
are initialized.
Page