DAV-DZ530, DAV-DZ630, HCD-DZ530, HCD-DZ630 - Sony Audio Service Manual (repair manual). Page 24

Read Sony DAV-DZ530 / DAV-DZ630 / HCD-DZ530 / HCD-DZ630 Service Manual online

24
HCD-DZ530/DZ630
(2) Select “2. Drive Manual Operation” by pressing the   2   button
on the remote commander. The screen will appear as shown.
(3) Select “3. Manual Adjustment” by pressing the  3  button on
the remote commander. The screen will appear as shown.
(4) Select “6.IOP” by pressing the  6  button on the remote
commander.
(5) Wait until a hexadecimal number appear.
(6) Convert each data from hexadecimal to decimal using
  conversion table.
(7) Please find the label on the rear of the BU (Base Unit).
 The default IOP value is written in the label.
(8) Subtract between these two values.
(9) If the remainder is smaller than 93 (decimal), then it is OK.
 However if the value is higher than 93, then the BU  is defective
 and need to be change.
(10) Press the  RETURN  button on the remote commander to
   return back to previous menu.
(11) Press the  0  button on the remote commander to return to
   Top Menu.
Drive Manual Operation
1. Servo Control
2. Track/Layer Jump
3. Manual Adjustment
4. Tray Aging Mode
5. MIRR time adjust
0. Return to Top Menu
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq Boost Adjust:
6. Iop:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
O o
    Change Value
[RETURN] Return to previous menu
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq Boost Adjust:
6. Iop. 58:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
[RETURN] Return to previous menu
O o
    Change Value
DVD SECTION
11. General Description
The IOP measurement allows you to make diagnosis and adjustment
simply by using the remote commander and monitor TV. The
instructions, diagnosis results, etc. are given on the on-screen display
(OSD).
Be sure to execute the IOP measurement when a BU (Base Unit) is
replaced.
12. How To Enter Test Mode
While pressing the  
x  
and    A  buttons simultaneously, turn
VOLUME  control in the direction of (+) with the DVD player in
power on.
The Test Mode starts, displayed “SERVICE IN” on this model
display then the menu shown below will be displayed on the TV
screen.
* The display of the “Model Name” of the “Remocon Diagnosis
Menu” change with the model and the destination. Refer to below
on the model name.
DZ530
: DS4
DZ630
: DS7
The menu above is the Remocon Diagnosis Menu screen which
consists of five main functions. At the bottom of the menu screen, the
model name and IF-con version. To exit from the Test Mode, press
the  ?/1  button on the remote commander.
13. Executing IOP Measurement
In order to execute IOP measurement, the following standard
procedures must be followed.
(1) In power on, while pressing the  
x  
and  A  buttons
simultaneously, turn the  VOLUME  control in the direction
of (+).
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version Information
Model Name
IF-con
: V
Syscon
: Ver.
er. XX.XX (XXXX)
X.XXX
: DS7_ XX
*
1
*1: Changes depending on destination 
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version information
Model Name
IF-con
:  Ver. XX.XX (XXXX)
Syscon
:  Ver. X.XXX
: DS7_ XX
*
1
*1: Changes depending on destination 
Page of 88
Display

Click on the first or last page to see other DAV-DZ530 / DAV-DZ630 / HCD-DZ530 / HCD-DZ630 service manuals if exist.