DAV-DZ340M, DAV-DZ640M, DAV-DZ840K, DAV-DZ840M, DAV-DZ940K, HBD-DZ340M, HBD-DZ640M, HBD-DZ840K, HBD-DZ840M, HBD-DZ940K - Sony Audio Service Manual (repair manual). Page 18

Read Sony DAV-DZ340M / DAV-DZ640M / DAV-DZ840K / DAV-DZ840M / DAV-DZ940K / HBD-DZ340M / HBD-DZ640M / HBD-DZ840K / HBD-DZ840M / HBD-DZ940K Service Manual online

HBD-DZ340M/DZ640M/DZ840K/DZ840M/DZ940K
18
6.  Color System Change (E3, E12, E15, PH, SP models)
•  Color system change to video signal format (NTSC/PAL).
Procedure:
1.  Press the [
?/1
] button to turn the set on.
2.  Press the [FUNCTION] button to set the function “DVD/CD”.
3.  Press the [
?/1
] button to turn the set OFF. 
4.  Press two buttons [FUNCTION] and [
?/1
] simultaneously, 
and the display of fl uorescent indicator tube changes to “PAL” 
or “NTSC”.
• Abbreviation
  E3 
: 240V AC area in E model
  E12 
: 220 – 240V AC area in E model
  E15 
: Iranian model
  PH 
: Philippines model
  SP 
: Singapore model
7.  TUNER TUNED/STEREO Display
•  The mode status of TUNED/STEREO is displayed.
1.  Press the [
?/1
] button to turn the power on.
2.  Press the buttons on the remote commander in the order given 
below to enter the Test Mode.
 [RETURN] 
t [4] t [0] t [0] t [8] t [ANGLE]
3.  The mode status is displayed by the corresponding segment.
 
On in STEREO mode
On during MODE IN
On in TUNED mode
(Indicated by the third segment from the top.)
4.  To terminate this mode, perform the operation described in 
Item 2 or turn the power off.
8.  PROTECTION  FACTOR  (SD  DETECTION/
DC  DETECTION/TSD  DETECTION)  IDENTIFICATION  
TEST  MODE
When an error is detected, the FL tube alternately displays 
“PROTECT” 
h “PUSH PWR”.
    r  Press the [
?/1
] button.
 
* Buttons other than the [
?/1
] button are invalid.
“STANDBY” blinks three times on the FL tube.
    
r
The protection release state (POWER OFF) is established.
(No FL tube display) 
    
r  Press the [
?/1
] button two times.
The power to the system turns on, and the normal operation is 
established. (Restore) 
During the protection state: 
1.   If the AC plug is connected or disconnected during the protec-
tion state, the protection state is released, and the normal op-
eration is established. (The protection state is not maintained.) 
2.   The protection factor is displayed by pressing the [RETURN] 
t [3] t [2] t [0] t [0] t [ANGLE] buttons of the re-
mote commander.
 
(during the “PROTECT” 
h “PUSH PWR” display).
 
k  When SD is detected: Repeats
   “SD 
ERR” 
h “PROTECT”.
 
k  When DC is detected: Repeats 
   “DC 
ERR” 
h “PROTECT”.
 
k  When TSD is detected: Repeats 
   “TMP 
ERR” 
h “PROTECT”.
PL:  SD detection
 
When the “L” output from the SD (shutdown) port on the 
S-MASTER POWER Driver Shutdown and voltage descent 
(15V or less) of 30V power supply (PVDD) are detected.
 DC 
detection
 
When the “L” output from the power/speaker error detection 
circuit (DC detection port) is detected for two seconds con-
tinually, the power system other than that of the FL tube is 
turned off, and the protection state is established.
 TSD 
detection
 
When the “L” output from the thermal shutdown port 
(TSDM) on the motor driver is detected.