Read Sony D-F21 / D-F22ST / ICD-BP220 Service Manual online
7
D-F21/F22ST
digital
voltmeter
voltmeter
100 k
Ω
TP81 (VT)
i
jack (J302)
set
16
Ω
level meter
(range: 0.5–5 V ac)
(range: 0.5–5 V ac)
Put the lead-wire
antenna close to
the set.
antenna close to
the set.
AM RF signal
generator
generator
TP3 (RF-IN)
FM RF signal
generator
generator
0.01
µ
F
set
TUNER SECTION 0 dB = 1 µV
• FM Section
Setting:
RADIO ON•BAND/MEMORY button : FM
STEP switch
RADIO ON•BAND/MEMORY button : FM
STEP switch
: 10k
75 kHz frequency
deviation by 1 kHz signal
output level : as low as possible
deviation by 1 kHz signal
output level : as low as possible
• AM Section
Setting:
RADIO ON•BAND/MEMORY button : AM
STEP switch
RADIO ON•BAND/MEMORY button : AM
STEP switch
: 10k
30% amplitude
modulation by
400 Hz signal
modulation by
400 Hz signal
• Connecting Level Meter (FM and AM)
• Connecting Digital Voltmeter (FM and AM)
• Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
done by the trimmer capacitors.
• For FM adjustment, fix the FM RF coil (L1) as shown next page
and then perform tracking adjustment at L2 and CT1.
Lastly check the voltage value.
Lastly check the voltage value.
• For AM adjustment, fix the ferrite-rod antenna (L3) as shown
next page and then perform tracking adjustment at L4 and CT3.
Lastly check the voltage value.
Lastly check the voltage value.
Adjustment Location: See page 8.
SECTION 4
ELECTRICAL ADJUSTMENTS
FM FREQUENCY COVERAGE
CHECK
Frequency Display
87.5 MHz
108 MHz
Reading on Digital voltmeter
2.5 ± 1.5 V
7.0 ± 4.0 V
Adjustment Part
<confirmation> <confirmation>
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L2
CT1
87.5 MHz
108 MHz
AM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T1
450 kHz
AM FREQUENCY COVERAGE
CHECK
Frequency Display
530 kHz
1,710 kHz
Reading on Digital voltmeter
1.0 ± 0.5 V
5.2 ± 0.7 V
Adjustment Part
<confirmation> <confirmation>
AM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L4
CT3
620 kHz
1,400 kHz