CX-LEM220 - Sony Audio Service Manual (repair manual). Page 13

Read Sony CX-LEM220 Service Manual online

13
CX-LEM220
CD SECTION
Note:
1. CD Block is basically constructed to operate without
adjustment.
2. Use YEDS-18 disc (3-702-101-01) unless otherwise indicated.
3. Use an oscilloscope with more than 10 M
Ω impedance.
4. Clean the object lens by an applicator with neutral detergent
when the signal level is low than specified value with the
following checks.
5. Check the focus bias check when optical block is replaced.
FOCUS BIAS CHECK
Procedure :
1. Connect the oscilloscope to TP012 (RFACO) and TP013 (VC)
on the BD board.
2. Insert the disc (YEDS-18). (Part No. : 3-702-101-01)
3. Press the [CD          ] button.
4. Confirm that the oscilloscope waveform is as shown in the
figure below. (eye pattern)
A good eye pattern means that the diamond shape (
◊) in the
center of the waveform can be clearly distinguished.
• RF signal reference waveform (eye pattern)
Checking Location:
VOLT/DIV: 0.2 V (with the 10: 1 probe in use.)
TIME/DIV: 500 ns
1.1
When observing the eye pattern, set the oscilloscope 
for AC range and raise vertical sensitivity.
0.2 Vp-p
NX
3. Mode: Playback
4. After the adjustments, apply suitable locking compound to
the parts adjusted.
Adjustment Location:Record/Playback/Erase Head
Tape Speed Check
Mode: Playback
1. Insert the WS-48B into the deck.
2. Press the N button on the deck.
3. Confirm that the frequency counter reads 3,000 
± 90 Hz.
Sample value of Wow and Flutter: 0.3% or less W.RMS (JIS)
(WS-48B)
set
test tape
P-4-A100
(10 kHz, – 10 dB)
R-CH
oscilloscope
L-CH
R-CH
V
H
waveform of oscilloscope
in phase 45
°
90
°
135
°
180
°
good
wrong
MAIN board
SPEAKER terminal (J302)
L-CH
+
set
test tape
WS-48B 
(3 kHz, 0 dB)
MAIN board
SPEAKER terminal (J302)
L-CH, R-CH
frequency counter
+
BD board
TP012 (RFACO)
TP013 (VC)
oscilloscope
(DC range)
– BD BOARD (Conductor Side) –
TP012
(RFACO)
TP013
(VC)
Page of 43