Read Sony CX-JV3 / JAX-V3 Service Manual online
18
CX-JV3
RFDC signal waveform
Connecting Location: BD board (Conductor Side)
(See page 19)
CD SECTION
Note:
1. Use YEDS-18 disc (3-702-101-01) unless otherwise indicated.
2. Use an oscilloscope with more than 10M
2. Use an oscilloscope with more than 10M
Ω impedance.
3. Clean the object lens by an applicator with neutral detergent when the
signal level is low than specified value with the following checks.
RFDC LEVEL CHECK
Connection:
Procedure:
1.
1.
Connect an oscilloscope to test point TP (RFDC) and TP (VC)
on the BD board.
on the BD board.
2.
Turn the power on.
3.
Put the disc (YEDS-18) in to playback the number five track.
4.
Confirm that oscilloscope waveform is clear and check RFDC
signal level is correct or not.
signal level is correct or not.
Note:
A clear RFDC signal waveform means that the shape “
◊” can be
clearly distinguished at the center of the waveform.
+
–
–
BD board
TP (RFDC)
TP (VC)
oscilloscope
VOLT/DIV: 200 mV
TIME/DIV: 500 ns
TIME/DIV: 500 ns
level: 0.6
±
0.15 Vp-p
RFAC LEVEL CHECK
Connection:
Procedure:
1.
1.
Connect an oscilloscope to test point TP (RFAC) and TP (VC)
on the BD board.
on the BD board.
2.
Turn the power on.
3.
Put the disc (YEDS-18) in to playback the number five track.
4.
Confirm that oscilloscope waveform is clear and check RFAC
signal level is correct or not.
signal level is correct or not.
Note:
A clear RFAC signal waveform means that the shape “
◊” can be
clearly distinguished at the center of the waveform.
RFAC signal waveform
Connecting Location: BD board (Conductor Side)
(See page 19)
+
–
–
BD board
TP (RFAC)
TP (VC)
oscilloscope
VOLT/DIV: 200 mV
TIME/DIV: 500 ns
TIME/DIV: 500 ns
level: 1.0
±
0.4 Vp-p
S-CURVE CHECK
Connection:
Procedure:
1.
1.
Connect an oscilloscope to test point TP (FE) and TP (VC)
on the BD board.
on the BD board.
2.
While depressing the key, insert an AC plug.
3.
Put the disc (YEDS-18) in and press the key and actuate
the focus search. (actuate the focus search when disc table is
moving in and out)
the focus search. (actuate the focus search when disc table is
moving in and out)
4.
Check the oscilloscope waveform (S-curve) is symmetrical
between A and B. And confirm peak to peak level within 2
between A and B. And confirm peak to peak level within 2
± 1
Vp-p.
S-curve waveform
Note:
• Try to measure several times to make sure than the ratio of A : B
or B : A is more than 10 : 7.
• Take sweep time as long as possible and light up the
brightness to obtain best waveform.
Connecting Location: BD board (Conductor Side)
(See page 19)
+
–
–
BD board
TP (FE)
TP (VC)
oscilloscope
A
B
symmetry
within 2
±
1 Vp-p
N
x
SECTION 5
ELECTRICAL ADJUSTMENTS
Click on the first or last page to see other CX-JV3 / JAX-V3 service manuals if exist.