29
2-18.  TUNER  BOARD  BLOCK, DAB  BOARD  BLOCK
2 DAB board block
2 TUNER board block
1 two screws 
 (BVTP3 
u 6)
(X5CD/X7CD)
(X5CDB/X7CDB)
– Main chassis block front bottom view –
CMT-X5CD/X5CDB/X7CD/X7CDB
30
2-19.  LID (POWER)  BLOCK
2-20.  ETHER  BOARD (X7CD/X7CDB)
3 bridge plate block
6 lid (power) block
5 three screws 
 (BVTP3 
u 6)
2 screw
 (BVTP3 
u 6)
1 BCO cushion
4 AC inlet (2P)
 (AC1)
5 screw
 (BVTP3 
u 6)
5 screw
 (BVTP3 
u 6)
OK
NG
‡+RZWRLQVWDOOWKH$&LQOHW3$&
–0DLQFKDVVLVEORFNIURQWERWWRPYLHZ–
Side with text.
Side without text.
– Lid (power) block top view –
3 ETHER board
1 screw 
 (BVTP3 
u 6)
2 Draw out the modular jack from hole.
Ver. 1.1
CMT-X5CD/X5CDB/X7CD/X7CDB
31
2-21.  MAIN  BOARD  BLOCK
4 three screws 
 (BVTP3 
u 6)
4 screw 
 (BVTP3 
u 6)
7 MAIN board block
6 connector
 (CN901)
coating clip
MAIN board
power unit (PWR1)
‡:LUHVHWWLQJ
5 Remove the MAIN board 
 
block in the direction
 
of the arrow.
1 Remove the wire 
 
from the coating clip.
3 flexible flat cable (7P)
 (CN502)
2 Peel off the
 adhesive 
sheet.
Note 1: When you install the connector, please install them correctly.
 
There is a possibility that this machine damages when not 
 
correctly installing it.
Insert is shallow
Insert is straight 
to the interior.
connector
Insert is incline
connector
connector
connector
connector
connector
OK
NG
NG
colored line
colored line
Insert is straight to the interior.
Insert is incline
flexible flat 
cable
flexible flat 
cable
connector
connector
OK
NG
Note 2: When installing the flexible flat cable, ensure that 
 
the colored line is not slanted after insertion.
(X5CD/X5CDB)
CMT-X5CD/X5CDB/X7CD/X7CDB
32
2-22.  MAIN  BOARD
6 MAIN board
‡:LUHVHWWLQJ
IC503
‡+RZWRLQVWDOOWKHVKHHW(0&DEVREHU
3 flexible flat cable (21P)
 (CN008)
1 flexible flat cable (15P)
 (CN904)
2 connector
 (CN703)
5 sheet
 (EMC-absober)
sheet
(EMC-absober)
C854 guide line
;&';&'%
flexible flat cable 
(15P)
ferrite core 
(FC3)
cushion
(jack ferrite)
guide line
IC503
C854
filament tape 
(sub material)
guide line
colored line
colored line
Insert is straight to the interior.
Insert is incline
flexible flat 
cable
flexible flat 
cable
connector
connector
OK
NG
Note 1: When you install the connector, please install them correctly.
 
There is a possibility that this machine damages when not
 
correctly installing it.
Insert is shallow
Insert is straight 
to the interior.
connector
Insert is incline
connector
connector
connector
connector
connector
NG
OK
NG
Note 2: When installing the flexible flat cable, ensure that 
 
the colored line is not slanted after insertion.
4 filament tape 
 (sub 
material)
guide line
Ver. 1.1