HCD-SPZ90DAB
SECTION  6
ELECTRICAL  ADJUSTMENTS
0 dB=0.775 V
DECK  SECTION
1. Demagnetize the record/playback head with a head
demagnetizer.
2. Do not use a magnetized screwdriver for the adjustments.
3. After the adjustments, apply suitable locking compound to the
parts adjust.
TEST  TAPE
RECORD/PLAYBACK  HEAD  AZIMUTH  ADJUSTMENT
Note:
Remove the mechanical deck before the adjust. (Refer to Section 3.
DISASSEMBLY (See page 6))
Procedure:
1. Mode:  Playback
2. Turn the adjustment screw and check output peaks. If the peaks
do not match for L-CH and R-CH, turn the adjustment screw
so that outputs match within 1dB of peak.
3. Mode:  Playback
4. After the adjustments, apply suitable locking compound to the
pats adjusted.
Tape
Signal
Used for
P-4-A063
6.3 kHz, –10 dB
Azimuth Adjustment
set
test tape
P-4-A063
(6.3 kHz, 
10 dB)
oscilloscope
V
H
waveform of oscilloscope
in phase 45
°
90
°
135
°
180
°
good
wrong
HP A-IN board
PHONES jack
(J982)
SECTION  5
MECHANICAL  ADJUSTMENTS
PRECAUTION
1. Clean the following parts with a denatured-alcohol-moistened
swab :
record/playback head
pinch roller
erase head
rubber belts
capstan
idlers
2. Demagnetize the record/playback head with a head
demagnetizer. (Do not bring the head magnetizer close to the
erase head.)
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, appiy suitable locking compound to
the parts adjusted.
5. The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
TORQUE  MEASUREMENT
Mode
Torque Meter
Meter Reading
2.9 – 7.4 mN
m
FWD
CQ-102C
(30 – 75 g
cm)
(0.42 – 1.04 oz
inch)
FWD
0.14 – 0.59 mN
m
Back Tension
CQ-102C
(1.5 – 6.0 g
cm)
(0.021 – 0.083 oz
inch)
more than 5.4 mN
m
FF/REW
CQ-201B
(more than 55 g
cm)
(more than 0.76 oz
inch)
TAPE  TENSION  MEASUREMENT
Mode
Tension Meter
Meter Reading
FWD
CQ-403A
more than 90 g
(more than 3.17 oz)
set
HP A-IN
PHONES jack
(J982)
+
level meter
test tape
P-4-A063
(6.3 kHz, 
10 dB)
Screw
position
L-CH
peak
within
1dB
Output
level
L-CH
peak
R-CH
peak
within
1dB
Screw
position
R-CH
peak
Page of 69