CMT-PX333, HCD-PX333 - Sony Audio Service Manual (repair manual). Page 83

Read Sony CMT-PX333 / HCD-PX333 Service Manual online

83
HCD-PX333
Pin No.
Pin Name
I/O
Description
44
XCAS
O
Column address strobe signal output to the D-RAM (IC152)    “L” active
45
A09
O
Address signal output to the D-RAM (IC152)
46
XRAS
O
Row address strobe signal output to the D-RAM (IC152)    “L” active
47
XWE
O
Write enable signal output to the D-RAM (IC152)    “L” active
48
D1
I/O
49
D0
I/O
50
D2
I/O
51
D3
I/O
52
MVCI
I (S)
Digital in PLL oscillation input from the external VCO    Not used (fixed at “L”)
53
ASYO
O
Playback EFM full-swing output terminal
54
ASYI
I (A)
Playback EFM asymmetry comparator voltage input terminal
55
AVDD
Power supply terminal (+3.3V) (analog system)
56
BIAS
I (A)
Playback EFM asymmetry circuit constant current input terminal
57
RFI
I (A)
Playback EFM RF signal input from the CXA2523AR (IC101)
58
AVSS
Ground terminal (analog system)
59
PCO
O (3)
Phase comparison output for master clock of the recording/playback EFM master PLL
60
FILI
I (A)
Filter input for master clock of the recording/playback master PLL
61
FILO
O (A)
Filter output for master clock of the recording/playback master PLL
62
CLTV
I (A)
Internal VCO control voltage input of the recording/playback master PLL
63
PEAK
I (A)
Light amount signal (RF/ABCD) peak hold input from the CXA2523AR (IC101)
64
BOTM
I (A)
Light amount signal (RF/ABCD) bottom hold input from the CXA2523AR (IC101)
65
ABCD
I (A)
Light amount signal (ABCD) input from the CXA2523AR (IC101)
66
FE
I (A)
Focus error signal input from the CXA2523AR (IC101)
67
AUX1
I (A)
Auxiliary signal (I
3
 signal/temperature signal) input from the CXA2523AR (IC101)
68
VC
I (A)
Middle point voltage (+1.65V) input from the CXA2523AR (IC101)
69
ADIO
O (A)
Monitor output of the A/D converter input signal    Not used (open)
70
AVDD
Power supply terminal (+3.3V) (analog system)
71
ADRT
I (A)
A/D converter operational range upper limit voltage input terminal (fixed at “H” in this set)
72
ADRB
I (A)
A/D converter operational range lower limit voltage input terminal (fixed at “L” in this set)
73
AVSS
Ground terminal (analog system)
74
SE
I (A)
Sled error signal input from the CXA2523AR (IC101)
75
TE
I (A)
Tracking error signal input from the CXA2523AR (IC101)
76
DCHG
I (A)
Connected to the +3.3V power supply
77
TEST4
I
Input terminal for the test    Not used (fixed at “H”)
78
ADFG
I (S)
ADIP duplex FM signal (22.05 kHz 
± 1 kHz) input from the CXA2523AR (IC101)
79
F0CNT
O
Filter f0 control signal output to the CXA2523AR (IC101)
80
XLRF
O
Serial data latch pulse signal output to the CXA2523AR (IC101)
81
CKRF
O
Serial data transfer clock signal output to the CXA2523AR (IC101)
82
DTRF
O
Writing serial data output to the CXA2523AR (IC101)
83
APCREF
O
Control signal output to the reference voltage generator circuit for the laser automatic power 
control
84
TEST0
O
Input terminal for the test    Not used (open)
85
TRDR
O
Tracking servo drive PWM signal (–) output to the BH6511FS (IC141)
86
TFDR
O
Tracking servo drive PWM signal (+) output to the BH6511FS (IC141)
87
DVDD
Power supply terminal (+3.3V) (digital system)
88
FFDR
O
Focus servo drive PWM signal (+) output to the BH6511FS (IC141)
* I (S) stands for schmitt input, I (A) for analog input, O (3) for 3-state output, and O (A) for analog output in the column I/O.
Two-way data bus with the D-RAM (IC152)
Page of 110
Display

Click on the first or last page to see other CMT-PX333 / HCD-PX333 service manuals if exist.