CMT-NEZ3, CMT-NEZ5, HCD-NEZ3, HCD-NEZ5 - Sony Audio Service Manual (repair manual). Page 13

Read Sony CMT-NEZ3 / CMT-NEZ5 / HCD-NEZ3 / HCD-NEZ5 Service Manual online

13
HCD-NEZ3/NEZ5
SECTION  5
MECHANICAL  ADJUSTMENTS
SECTION  6
ELECTRICAL  ADJUSTMENTS
Precaution
1. Clean the following parts with a denatured-alcohol-moistened
swab :
record/playback head
pinch roller
erase head
rubber belts
capstan
idlers
2. Demagnetize the record/playback head with a head
demagnetizer. (Do not bring the head magnetizer close to the
erase head.)
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, appiy suitable locking compound to
the parts adjusted.
5. The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
Torque Measurement
Mode
Torque Meter
Meter Reading
2.95 – 6.86 mN
m
FWD
CQ-102C
(30 – 70 g
cm)
(0.42 – 0.97 oz
inch)
FWD
0.15 – 5.39 mN
m
Back Tension
CQ-102C
(1.5 – 5.5 g
cm)
(0.021 – 0.076 oz
inch)
more than 5.89 mN
m
FF
CQ-201B
(more than 60 g
cm)
(more than 0.83 oz
inch)
more than 5.89 mN
m
REW
CQ-201B
(more than 60 g
cm)
(more than 0.83 oz
inch)
Tape Tension  Measurement
Mode
Tension Meter
Meter Reading
FWD
CQ-403A
more than 100 g
(more than 3.53 oz)
0 dB=0.775 V
DECK  SECTION
Procedure:
1. Mode:  Playback
set
HEAD PHONE board
PHONES jack
(J500)
+
level meter
test tape
P-4-A063
(6.3 kHz, –10 dB)
1. Demagnetize the record/playback head with a head
demagnetizer.
2. Do not use a magnetized screwdriver for the adjustments.
Test Tape
RECORD/PLAYBACK  HEAD  AZIMUTH  ADJUSTMENT
Note:
Remove the cover (azimuth) before this adjustment.
Tape
Signal
Used for
P-4-A063
6.3 kHz, -10 dB
Azimuth Adjustment
Page of 50