CMT-NEZ3, CMT-NEZ5, HCD-NEZ3, HCD-NEZ5 (serv.man2) - Sony Audio Service Manual (repair manual). Page 7

Read Sony CMT-NEZ3 / CMT-NEZ5 / HCD-NEZ3 / HCD-NEZ5 (serv.man2) Service Manual online

7
HCD-NEZ3/NEZ5
0 dB=0.775 V
DECK  SECTION
set
HEAD PHONE board
PHONES jack
(J500)
+
level meter
test tape
P-4-A063
(6.3 kHz, –10 dB)
1. Demagnetize the record/playback head with a head
demagnetizer.
2. Do not use a magnetized screwdriver for the adjustments.
Test Tape
Tape
Signal
Used for
P-4-A063
6.3 kHz, -10 dB
Azimuth Adjustment
RECORD/PLAYBACK  HEAD  AZIMUTH  ADJUSTMENT
Note:
Remove the cover (azimuth) before this adjustment.
Procedure:
1. Mode:  Playback
3.
ELECTRICAL  ADJUSTMENTS
set
test tape
P-4-A063
(6.3 kHz, –10 dB)
oscilloscope
V
H
waveform of oscilloscope
in phase 45
°
90
°
135
°
180
°
good
wrong
HEAD PHONE board
PHONES jack
(J500)
Screw
position
L-CH
peak
within
1dB
Output
level
L-CH
peak
R-CH
peak
within
1dB
Screw
position
R-CH
peak
2. Turn the adjustment screw and check output peaks. If the peaks
do not match for L-CH and R-CH, turn the adjustment screw
so that outputs match within 1dB of peak.
3. Mode:  Playback
4. After the adjustments, apply suitable locking compound to
the pats adjusted.
Adjustment Location: Record/Playback/Erase Head
Page of 43