CMT-M100MD, HCD-M10 - Sony Audio Service Manual (repair manual). Page 26

Read Sony CMT-M100MD / HCD-M10 Service Manual online

26
HCD-M10
7. AUTOMATIC SELF-DIAGNOSIS FUNCTION
This test mode performs CREC and CPLAY automatically for mainly checking the characteristics of the optical pick-up.
To perform this test mode, the laser power must first be checked.
Perform AUTO CHECK after the laser power check and Iop Compare.
Procedure:
1.
Press the ENTER/YES “R” button. If “LDPWR 
 ” is displayed, it means that the laser power check has not been performed.
In this case, perform the laser power check and Iop Compare (C27), and then repeat from step1.
2.
If a disc is in the mechanical deck, it will be ejected forcibly.
“DISC IN” will be displayed in this case. Load a test disc (MDW-74/GA-1) which can be recorded.
3.
If a disc is loaded at step 2, the check will start automatically.
4.
When “XX CHECK” is displayed, the item corresponding to XX will be performed.
When “06 CHECK” completes, the disc loaded at step 2 will be ejected. “DISC IN” will be displayed. Load the check disc (TDYS-1).
5.
When the disc is loaded in step 4, the check will automatically be resumed from “07 CHECK”.
6.
After completing to “12 CHECK”, check OK or NG will be displayed. If all items are OK, “CHK ALL OK” will be displayed. If any
item is NG, it will be displayed as “NG:xxxx”.
When “CHK ALL OK” is displayed, it means that the optical pick-up is normal. Check the operations of other parts (spindle motor, sled
motor, etc.).
When displayed as “NG:xxxx”, it means that the optical pick-up is faulty. In this case, replace the optical pick-up.
Page of 92
Display

Click on the first or last page to see other CMT-M100MD / HCD-M10 service manuals if exist.